NYC-WTC_000371828
ATC indoor air quality report for PS 234M; measurements collected in April 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗ATC measurements for PS 234M under BOE program.
NYC-WTC_000314974–000314978OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan April 15,2002 Indoor Air Quality Assessment Page 4 P. S. 234M_________________________________________ ATC Project No. 15-19125-0279 45 p,g/m3. None of the outdoor measurements for PM2.5 were above the NPAAQS of 65 pg/m^ 24- hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Five (5) of the nine (9) instantaneous outdoor readings were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children.
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
TVOC Concentration
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm.
OBSERVATIONS
During this assessment, ATC noted the following: • The building was occupied at the time of the assessment; • No smoke odor was detected in the building.
FINDINGS
Based on the real-time measurements, the following findings are presented;
1. Concentrations of CO and TVOCs were below applicable standards and guidelines. 2. One (1) of the indoor measurements for carbon dioxide was above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The highest reading was taken in room 304 (1202 ppm) at 2:25 PM with 25 occupants. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration. 3. All of the indoor measurements for temperature were within the range of 68 to 75°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). 4. One (1) of the indoor measurements for relative humidity was below and fifty (50) were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. 5. None of the indoor measurements for PM2,5 were above the NPAAQS of 65 pg/m^ 24- hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children. None of the outdoor measurements for PM2.5 were above the NPAAQS of 65 pg/m3 24- hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Five (5) of the nine (9) instantaneous outdoor readings were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children.
CITY_21MC100_003032234
NYC-WTC_000314977
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000371828
ATC indoor air quality report for PS 234M; measurements collected in April 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397276
IAQ measurements report for PS 234M; April 12, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000222495
ATC Associates letter submitting indoor air quality measurement results collected on April 19, 2002, at P.S. 89M for the NYC Board of Education.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369706
ATC report of IAQ measurements at PS 89M, May 2002, for BOE evaluation.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392718
ATC report of IAQ measurements collected at the referenced school.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392661
IAQ report dated April 22, 2002 for PS 89M; BOE evaluation requested.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313339
ATC IAQ memo detailing measurements and scope of work at PS 89M.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392743
ATC IAQ measurements conducted at P.S. 89M for NYC BOE.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313578
ATC IAQ measurements at PS 89M for school building evaluation.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220651
Formal indoor air quality assessment report submitted to the Board of Education regarding measurements taken at PS 89M on April 17, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394501
Indoor air quality measurements collected April 29, 2002 at the school.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383864
ATC report of IAQ measurements collected at P.S. 89M for BOE evaluation.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000371828
ATC indoor air quality report for PS 234M; measurements collected in April 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397276
IAQ measurements report for PS 234M; April 12, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000259086
ATC indoor air quality report for the High School of Economics and Finance, March 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000402524
Indoor air quality measurements collected March 19, 2002 at the referenced school.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000384236
Indoor air quality measurements collected at HS Economics & Finance for BOE program.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000259136
Indoor air quality measurements report for the High School of Economics and Finance, March 2002.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000371828
ATC indoor air quality report for PS 234M; measurements collected in April 2002.
Similar indexed content
NYC-WTC_000397276
IAQ measurements report for PS 234M; April 12, 2002.
Similar indexed content
NYC-WTC_000222495
ATC Associates letter submitting indoor air quality measurement results collected on April 19, 2002, at P.S. 89M for the NYC Board of Education.
Similar indexed content
NYC-WTC_000369706
ATC report of IAQ measurements at PS 89M, May 2002, for BOE evaluation.
Similar indexed content
NYC-WTC_000392718
ATC report of IAQ measurements collected at the referenced school.
Similar indexed content