IAQ report, P.S. 234M, Apr 12 2002

Machine-extracted title · confidence 39%

ATC measurements for PS 234M under BOE program.

NYC-WTC_000314974–000314978
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan April 15,2002 Indoor Air Quality Assessment Page 4 P. S. 234M_________________________________________ ATC Project No. 15-19125-0279 45 p,g/m3. None of the outdoor measurements for PM2.5 were above the NPAAQS of 65 pg/m^ 24- hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Five (5) of the nine (9) instantaneous outdoor readings were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children.

* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.

TVOC Concentration

TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm.

OBSERVATIONS

During this assessment, ATC noted the following: • The building was occupied at the time of the assessment; • No smoke odor was detected in the building.

FINDINGS

Based on the real-time measurements, the following findings are presented;

1. Concentrations of CO and TVOCs were below applicable standards and guidelines. 2. One (1) of the indoor measurements for carbon dioxide was above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The highest reading was taken in room 304 (1202 ppm) at 2:25 PM with 25 occupants. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration. 3. All of the indoor measurements for temperature were within the range of 68 to 75°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). 4. One (1) of the indoor measurements for relative humidity was below and fifty (50) were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. 5. None of the indoor measurements for PM2,5 were above the NPAAQS of 65 pg/m^ 24- hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children. None of the outdoor measurements for PM2.5 were above the NPAAQS of 65 pg/m3 24- hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Five (5) of the nine (9) instantaneous outdoor readings were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children.

CITY_21MC100_003032234

NYC-WTC_000314977

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000314977Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

IAQ report for PS 89M, Apr 2002 · Box unavailable

NYC-WTC_000220651

Formal indoor air quality assessment report submitted to the Board of Education regarding measurements taken at PS 89M on April 17, 2002.

12 shared non-person entities · 1 shared topics · similarity 0.998

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →