NYC 9/11 Public Portal Document
ATC Associates
104 East 25 Street, New York, NY 10010
Phone: (212) 353-8280 Fax: (212) 353-8306
Attn: Mr. Bernard Orlan Received: 1/23/02 5:00:00 AM
N.Y.C. Board of Education
28-11 Queens Plaza North ATC Group#: 6409
Long Island City, NY 11101 Analysis Date: 1/23/02
Fax: (212)475-4122 Phone: (212) 477-8941
Project: PS 89M 201 Warren Street, New York, NY
Playground, Roof 2- 5± Floor, 1st Floor Hallway
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
>lrea Non. Asbestos • Structures Sensitivity Concentration
Sample l^olume Analyzed Asb O.Sfi-5 Sfi (S/cc) (S/mm^) (S/cc) Notes
01 1920.00 0.0450 0 NoneDetected 0 0 0.0045 <22.24 <0.0045
6409 -1
02 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045
6409 -2
03 1848.00 0.0450 0 NoneDetected 0 0 0.0046 <22.24 <0.0046
6409 -3
04 1840.00 0 0450 0 NoneDetected 0 0 0.0047 <22.24 <0.0047
6409 -4
05 2088.00 0 0450 0 NoneDetected 0 0 0.0041 <22.24 <0.0041
6409 -5
06 1992.00 0.0450 0 None Detected 0 0 0.0043 <22.24 < 0.0043
. 6409 -6
07 1810.00 0.0450 0 NoneDetected 0 0 0.0047 <22.24 <0.0047
6409 -7
08 1840.00 0.0450 0 NoneDetected 0 0 0.0047 <22.24 <0.0047
6409 -8
MARKPEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: ___ ■ 5 DvedJjy:
Disclaimer: The laboratory is not responsible for data reported in stnictures/cc, which is dependent oti volume collected by non-laboratory personnel. This lab is only responsible
for data reported in stnictures/mml This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLM’EM #101187-0, NY State ELAP #10879
CITY_21MC100_003047131