NYC 9/11 Public Portal Document
104 East 25th St
New York, New York 10010
www.atc-envirQ.com
212.353.8280
Fax 212.353.8306
ASSOCIATES INC.
February 14, 2002
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Metals
Stuyvesant High School
ATC Project No. 15-19125-0246
Dear Mr. Orlan;
ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for metals in
airborne dust on January 30, 2002, at the referenced school. The New York City Board of
Education (BOE) requested this sampling at the recommendation of H. A. Bader, a consultant
retained by the parents association.
Scope of Work
ATC collected three (3) samples for metals at specified locations. Samples were collected for
eight (8) hours using 37 mm mixed cellulose ester filter connected to battery-powered sampling
pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and after each sampling
period. Two (2) samples were collected inside the building and one (1) was collected on the roof.
One blank sample was also submitted. The samples were sent to PSC Analytical Services, Inc.,
an American Industrial Hygiene Association-accredited laboratory in Reading, PA. Analysis was
perfonned by NIOSH Methods 73OOM. Each sample was analyzed for a panel of eleven (11)
metals. The metals were aluminum (Al), cadmium (Cd), chromium (Cr), cobalt (Co), copper
(Cu), iron (Fe), magnesium (Mg), manganese (Mn), molybdenum (Mo), nickel (Ni) and zinc
(Zn). A copy of the analytical report is attached.
The sampling locations, specified by the parents association consultant, were as follows:
• P'floor lobby;
• 2”'* floor bridge entrance hallway;
• Roof by the air intake.
The established regulatory values for metals are intended for industrial workplace exposures and
are not generally applicable to office/school settings. There are no standards for metals in indoor
air in non-industnal situations. The Environmental Protection Agency has recommended a
screening level for hexavalent Cr (the more toxic form) of 0.6 micrograms per cubic meter of air
(0.6 ug/m’). These above samples were analyzed for total Cr. The EPA level is based on
continuous exposure to hexavalent chromium for one year.
CITY_21MC100_003046829
NYC-WTC_000312711
OCR can misread numbers and units. Confirm readings against the page image before using them.