NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Eim Street Suite 200
^ace Analytical" Minneacolis. MN 55414
Phone: 612.607 1700
www.pacelabs.com REPORT OF: CHEMICAL ANALYSES
Fax: 612.807.6444
PROJECT; PCDD/PCDF ANALYSES DATE: November 27, 2001
ISSUED TO: ATC Associates REPORT NO: 01-1050848
Attn: Mr. Jim Cohn
104 East 25th Street, 10th Floor
New York, NY 10010
INTRODUCTION
This report presents the results from the analyses performed on four samples which were
submitted by a representative of ATC Associates The samples were analyzed for the presence or
absence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) using a modified
version of USEPA Method 8290 as described below.
SAMPLE IDENTIFICATION
Client ID Sample Type Date Received Pace ID
ATC-1108-01 Wipe 11/09/01 103124673
ATC-1108-02 Wipe 11/09/01 103124681
. ATC-1108-03 Wipe 11/09/01 103124699
L ATC-1108-04 Wipe 11/09/01 103124707
METHODOLOGY
Sample Extraction
A portion of each sample was spiked with ^2Ci2-labeled PCDD/PCDF internal standards (Table 1)
and extracted with toluene in a Soxhlet extractor. The extract was quantitatively transferred to a
Kuderna-Danish concentrator, concentrated, and solvent exchanged to hexane. The hexane extract
was then spiked with 2,3,7,8-TCDD-^’Cl4 enrichment efficiency standard (Table 1) and processed
through the analyte enrichment procedures described below.
»
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.