NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street, Suite 200
^ace Analytical" REPORT OF: CHEMICAL ANALYSES
Minneapolis, Ml\l 55414
Phone: 612.607.1700
www.pacelabs.com Fax: 612.607.6444
PROJECT: PCDD/PCDFANALYSES DATE: April 5, 2002
ISSUED TO: ATC Associates REPORT N0:02-1055016
Attn: Mr. Jim Cohn
104 East 25th Street, 1 0th Floor
New York, NY 10010
INTRODUCTION
This report presents the results from the analyses performed on three samples that were submitted
by a representative of ATC Associates. The samples were analyzed for the presence or absence of
polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) using a modified version of
USEPA Method 8290 as described below.
SAMPLE IDENTIFICATION
Client ID Sample Type Date Received Pace ID
ATC-0308-89M-DX1 Wipe 03/12/02 103384756
ATC-0308-89M-DX2 Wipe 03/12/02 103384764
ATC-0308-89M-DX3 Wipe 03/12/02 103384772
METHODOLOGY
Sample Extraction
Each sample was spiked with '^Cu-labeled PCDD/PCDF internal standards (Table 1) and extracted
with toluene in a Soxhlet extractor. The extract was quantitatively transferred to a Kuderna-Danish
concentrator, concentrated, and solvent exchanged to hexane. The hexane extract was then
spiked with 2,3,7,8-TCDD-^'Cl. enrichment efficiency standard (Table 1) and processed through
the analyte enrichment procedures described below.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
nelac
CITY_21MC1OO_OO539O294