104 East 25th Street *' New York, New York lOOlO www.atc- snviro.corr, 212.353.8280 rax 212.353.8306 ASSOCIATES INC.

October 10, 2001

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101 -4008

Re; Indoor Air Quality Assessment Stuyvesant High School 345 Chambers St. New York, New York ATC Project No. 15-19125-0246

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide tins report of an indoor air quality (lAQ) assessment conducted on October 9, 2001, at the referenced school. The New York City Board of Education (BOE) requested this assessment to determine if acceptable indoor air quality is being maintaned.

SCOPE OF WORK

ATC conducted this evaluation to assess the basic parameters of temperature, relative humidity, carbon dioxide (CO,) and carbon monoxide (CO).

Total volatile organic compounds (TVOCs) and respirable particulates were also measured.

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists, of ATC’s New York City office, conducted the assessment. ATC’s findings and conclusions are based on a visual inspection, real-time environmental measurements and conditions present in the school at the time of the assessment.

ATC measured temperature, relative humidity, CO, and CO with a Q-Trak® Model 8551, manufactured by TSI, Inc.

ATC measured concentrations of respirable particulates with a Dust-Trak® Aerosol Monitor Model 8520, manufactured by TSI, Inc.

ATC measured concentrations of TVOCs using a R,YE Systems, Inc. MiniRAE® photoionization detector (PID).

CITY_21MC100_0 03045485

NYC-WTC_000311687

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000311687Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000292885

IAQ field report for Stuyvesant High School dated Oct 16, 2001.

Similar indexed content

Indoor air quality report, October 2001

NYC-WTC_000197534

Letter from ATC Associates reporting an indoor air quality assessment conducted at a Board of Education school in October 2001.

Similar indexed content

Compare copies and versions →