NYC-WTC_000312350
Attachment with analytical lab report for CITY_21MC100_003046195 and related identifiers.
9 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Attachment page for PCDDs & PCDFs lab analysis.
NYC-WTC_000310935–000310949OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document .....
^ace Analytical' Vinneupc'hs. MN 55414 Phene: 512.607.1700 wwwpacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 512.807.6444
PROJECT: PCDD/PCDFANALYSES DATE: April 5, 2002
PAGE; 5 REPORT NO: 02-1055017
PCDD/PCDF Quantific and Calculations (Cont.) Each pair of ion mass peaks in the selected-ion-current chromatograms was evaluated manually to determine if it met the criteria for a PCDD or PCDF isomer. Areas of ail peaks exhibiting correct ion ratios, having retention times within the correct windows, and having areas corresponding to concentrations in the range covered by the initial calibration were then summed for calculations of total congener concentrations. The toxic equivalence of each sample was calculated using the factors listed in Table 5.
A limit of detection (LOD) based on producing a signal that is 2.5 times the noise level, was calculated for each undetected 2,3,7,8-substituted isomer of any tetra through octa chlorinated congener class. The noise heights used to calculate the detection limits were measured at the retention time of the specific isomer. The formula used for calculating the LOD is:
Hn X Qis X 2.5 LOD = His X W X Rf where:
LOD Single isomer limit of detection Hn Sum of noise heights at native isomer retention time Qis Quantity of labeled internal standard His Sum of peak heights for labeled internal standard W Sample amount Rf Response factor
The recovery of the 2,3,7,8-TCDD-^’Cl4 enrichment efficiency standard and each ’’C,2-labeled internal standard, relative to either 1,2,3,4-TCDD-’^Ci2 or 1,2,3,7,8,9-HxCDD-”Ci2, was calculated using the following equation;
Ais X Qrs x 100% %R = Rfr X Ars x Qis where:
%R = Percent recovery of labeled internal standard Ais = Sum of integrated areas of labeled internal standard Qrs = Quantity of recovery standard Ars = Sum of integrated areas of recovery standard Rfr = Response factor of the specific labeled internal standard relative to the recovery standard Qis = Quantity of the labeled internal standard congener added to the sample
REPORr OF LMMMTORY AIMLYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.
/nel^i CITY_21MC100_003029233
NYC-WTC_000310941
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000312350
Attachment with analytical lab report for CITY_21MC100_003046195 and related identifiers.
9 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326586
Analytical lab report segment for PCDDs & PCDFs; city file reference.
8 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202123
Attachment containing laboratory analysis results for polychlorinated dibenzo-p-dioxins and dibenzofurans at the NYC WTC site.
8 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326628
Analytical lab report for PCDDs & PCDFs; city file reference.
8 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000175725
Confidential attachment containing analytical laboratory reports regarding polychlorinated dibenzo-p-dioxins and furans under a protective order.
9 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383409
Laboratory report detailing analyses for dioxins at client location, with project identifiers.
9 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240874
Attachment page of confidential PCDD/PCDF lab reports for NYC-WTC chain.
8 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382417
PACE report: PCDD/PCDF levels for ATC project at 104 East 25th Street.
9 shared non-person entities · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383442
Laboratory analysis report for project 19125-0297, client ATC, NYC BOE, multi-page document.
9 shared non-person entities · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383373
PACE lab report for ATC project 19125-0297; overview of method 8290.
9 shared non-person entities · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300414
Report of PCDD/PCDF determinations for ATC project; laboratory details and client info on file.
9 shared non-person entities · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256565
PACE Analytical report/dossier with NYC project details and determinations.
9 shared non-person entities · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000399532
Laboratory analysis report for PCDD/PCDF on ATC project 19125-0279, 104 East 25th Street.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312350
Attachment with analytical lab report for CITY_21MC100_003046195 and related identifiers.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250132
Determination of PCDD/PCDF levels for ATC client at 104 East 25th Street.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383409
Laboratory report detailing analyses for dioxins at client location, with project identifiers.
Similarity score 0.976 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000249257
PACE Analytical report on PCDD/PCDF analyses submitted by ATC, Jan 2002.
Similarity score 0.976 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382417
PACE report: PCDD/PCDF levels for ATC project at 104 East 25th Street.
Similarity score 0.976 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Attachment with analytical lab report for CITY_21MC100_003046195 and related identifiers.
Similar indexed content
NYC-WTC_000326586
Analytical lab report segment for PCDDs & PCDFs; city file reference.
Similar indexed content
NYC-WTC_000202123
Attachment containing laboratory analysis results for polychlorinated dibenzo-p-dioxins and dibenzofurans at the NYC WTC site.
Similar indexed content
Analytical lab report for PCDDs & PCDFs; city file reference.
Similar indexed content
NYC-WTC_000175725
Confidential attachment containing analytical laboratory reports regarding polychlorinated dibenzo-p-dioxins and furans under a protective order.
Similar indexed content