104 East 25th St New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

January 23, 2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Re: Air Samples for Polychlorinated Biphenyls High School of Economics and Finance ATC Project No. 15-19125-0291

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of the results of air samples for polychlorinated biphenyls (PCBs) collected on January 22, 2002, at the referenced location. The New York City Board of Education (BOE) requested these samples to evaluate possible contamination in the school building.

SCOPE OF WORK

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists of ATC’s New York City office, collected the samples.

The samples were collected using glass fiber filters and Florisil® tubes connected in series to battery-powered sampling pumps set at a flow rate of 0.2 liters per minute. The sampling time was ten (10) hours. The samples were analyzed by PSC Analytical Services, Inc. (PSC), an American Industrial Hygiene Association-accredited laboratory in Reading, PA. Analysis was performed according to NIOSH Method 5503 (gas chromatography/electron capture detector).

The sampling was performed consistent with generally accepted industrial hygiene practices. There were inherent limitations created by constraints of time, operational and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates the samples were collected.

SAMPLING RESULTS

ATC submitted nine (9) samples for PCBs (plus one blank) to PSC for analysis. Each sample was analyzed for seven (7) PCBs with different chlorine contents. Copies of the laboratory reports are provided in the Attachment.

Samples were collected from locations throughout the building. The sampling locations were: Outdoors at the Main Entrance, the Main Lobby, 3rd floor Hallway by Stair B, 5th floor by Stair A, 7th floor Hallway by the bridge, 8th floor Kitchen, Room 906, Room 1006 and the Roof by the air intake.

CITY_21MC100_003029066

NYC-WTC_000310791

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000310791Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →