Air sampling report, M833 building

Machine-extracted title · confidence 52%

ATC air sampling report for M833 school building, Feb 23, 2002, toxic organics.

NYC-WTC_000310776–000310779
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St., 10th Floor New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

March 8, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Toxic Organic Compounds High School of Economics and Finance (M833) ATC Project No. 15-19125-0291

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for toxic organic compounds conducted on February 23, 2002, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of Emteque, the consultant to the parents association.

ATC collected two (2) air samples for toxic organic compounds (TOC). Samples were collected for a minimum of one hundred minutes using Supelco® sampling tubes connected to battery- powered sampling pumps at a flow rate of 0.15 liters per minute. Pumps were calibrated before and after each sampling period. One (1) sample was collected inside the building and one (1) was collected outside. The sample tubes were prepared and analyzed by PSC Analytical Services, Inc., an American Industrial Hygiene Association-accredited laboratory in Reading, PA. Analysis was performed by gas chromatography/mass spectrometry according to EPA Method TO-l/TO-2 (TO-17).

Each sample was analyzed for a panel of twenty-three (23) specific TOCs. These compounds were; acrylonitrile, allyl chloride, benzene, bromobenzene, carbon tetrachloride, chlorobenzene, chloroform, cumene, 1, 2-dichloroethane, I, 2-dichloropropane, 1, 3-dichloropropane, ethyl benzene, ethylene dibromide, heptane, 1-heptene, methylene chloride, tetrachloroethene, toluene, 1, 1, 1-trichloroethane, trichloroethene, vinylidene chloride, vinyl chloride and xylenes. In addition, unidentified peaks on the chromatogram were compared against the mass spectrograph’s library of organic compounds (“library search”) for possible identification..

The sampling locations were outside the main entrance and the 1“ floor lobby by the elevators.

TOC Panel Results Nine of the TOCs in the panel were detected in the samples. Unknown peaks were also found in each sample. The TOCs identified from the panel are shown in Table 1. A copy of the analytical report is provided in Attachment 1.

CITY_21MC100_003029050

NYC-WTC_000310776

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000310776Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →