NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Real-time air monitoring report, BOE, 104 East 25th St, Mar

Machine-extracted title · confidence 41%

ATC findings for March 22, 2002 respirable particulates monitoring at multiple locations.

NYC-WTC_000310321–000310322
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan March 25, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314

■■ TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*

Respirable 65 micrograms per cubic Particulates meter of air (jig/nP) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Particulates 40 gg/m3 24 hour average for children/sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

A total of sixty-five (65) respirable particulates measurements* were collected from twenty-nine locations in Manhattan, ranging from W. 11* Street to E. 33’^*’ Street. The measurements were made from 5:30 A.M. to 4:25 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PM2.5 concentrations ranged from 6 pg/m^ to 38 (ig/m^. The indoor concentrations ranged from 5 (ig/m^ to 29 p.g/m3. None of the indoor or outdoor readings were above the NPAAQS of 65 pg/m^ or above the EPA recommended guideline for children and sensitive individuals of 40gg/m3.

• These measurements were instantaneous readings',* the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, none of tlie indoor or outdoor readings were above the NPAAQS of 65 M-g/m^ or above the EPA recommended guideline for children and sensitive individuals of 40 ug/m^.

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.

Sincerely, ATC ASSOCIATES INC.

tS/Yiannis EfstatKiou James R. Cohn, CIH, CSP Project Manager Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC100_003043963

NYC-WTC_000310322

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000310322Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Air monitoring, March 6, 2002

NYC-WTC_000310297

ATC report of real-time respirable particulates at BOE locations on March 6, 2002.

Similar indexed content

Compare copies and versions →