NYC-WTC_000310197
ATC report of respirable particulates monitoring at multiple NYC BOE locations in Mar 2002.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗ATC report of real-time respirable particulates at BOE locations on March 6, 2002.
NYC-WTC_000310297–000310298OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan March 6, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314
TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*
Respirable 65 micrograms per cubic Particulates meter of air (pg/mi^) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Particulates 40 fxg/m3 24 hour average for children/ sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
A total of sixty-seven (67) respirable particulates measurements* were collected from thirty locations in Manhattan, ranging from W. 11* Street to E. 33* Street. The measurements were made from 5:45 A.M. to 4:40 P.M. The lAQ field report forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 21 (ig/m^ to 34 )ig/m3. The indoor concentrations ranged from 13 gg/m^ to 32 gg/m^. None of the indoor or outdoor readings were above the NPA^AQS of 65 gg/m^ or above the EPA recommended guideline for children and sensitive individuals of 40p,g/m3.
• These measurements were instantaneous readings', ’ the NPAAQS and the recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, none of tlie indoor or outdoor readings were above the NPAAQS of 65 pg/m^ or above the EPA recommended guideline for children and sensitive individuals of 40 pg/m3.
It is our pleasure to provide these air qufdity consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.
Sincerely, ATC ASSOCIATES INC.
niannis Efstathiou James R. Cohn, CIH, CSP Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CITY_21MC100_003043833
NYC-WTC_000310298
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000310197
ATC report of respirable particulates monitoring at multiple NYC BOE locations in Mar 2002.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310295
ATC monitoring of respirable particulates at multiple NYC BOE locations on March 5, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310282
ATC report of respirable particulates measured Feb 14, 2002 for BOE locations.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315781
ATC report of respirable particulates monitoring conducted March 20, 2002 for BOE.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353112
ATC report of respirable particulates monitoring at multiple NYC BOE locations, Feb 2002.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310195
ATC report of respirable particulates monitoring at multiple NYC BOE locations in Mar 2002.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310323
ATC report of March 26, 2002 respirable particulates monitoring at numerous sites.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353168
ATC provides real-time respirable particulates monitoring results for the BOE, March 4, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208202
ATC report on real-time air monitoring of respirable particulates at multiple locations on February 27, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310291
ATC results of respirable particulates monitored Feb 28–Mar 1, 2002 for BOE.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310321
ATC findings for March 22, 2002 respirable particulates monitoring at multiple locations.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310319
ATC report for March 21, 2002 monitor locations and results of respirable particulates.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000310323
ATC report of March 26, 2002 respirable particulates monitoring at numerous sites.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310197
ATC report of respirable particulates monitoring at multiple NYC BOE locations in Mar 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310295
ATC monitoring of respirable particulates at multiple NYC BOE locations on March 5, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353112
ATC report of respirable particulates monitoring at multiple NYC BOE locations, Feb 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310282
ATC report of respirable particulates measured Feb 14, 2002 for BOE locations.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315781
ATC report of respirable particulates monitoring conducted March 20, 2002 for BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000310197
ATC report of respirable particulates monitoring at multiple NYC BOE locations in Mar 2002.
Similar indexed content
NYC-WTC_000310295
ATC monitoring of respirable particulates at multiple NYC BOE locations on March 5, 2002.
Similar indexed content
NYC-WTC_000310282
ATC report of respirable particulates measured Feb 14, 2002 for BOE locations.
Similar indexed content
NYC-WTC_000315781
ATC report of respirable particulates monitoring conducted March 20, 2002 for BOE.
Similar indexed content
NYC-WTC_000353112
ATC report of respirable particulates monitoring at multiple NYC BOE locations, Feb 2002.
Similar indexed content