NYC 9/11 Public Portal Document
104 East 25th St, 10th Fl
New York, New York 10010
wwwatc-enviro com
212 353 8280
Fax 212 353 8306
ASSOCIATES INC
August 30, 2002
Mr Bernard P Orlan
Director, Environmental Health and Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Mercury Vapor
Alfred E. Smith School (P. S. IM)
ATC Project No. 15-19125-0340
Dear Mr Orlan
ATC Associates, Inc. (ATC) is pleased to provide this report of the results of air sampling for
mercury (Hg) vapor conducted on August 27, 2002, at the referenced school The New York City
Department of Education (DOE) requested this sampling prior to the resumption of classes to
verify that acceptable indoor air quality is being maintained
I
Scope of Work
ATC collected three (3) samples for Hg vapor using Carulite® (Hydrar) tubes connected to
battery-powered sampling pumps calibrated to collect 0 2 liters of air per minute The samples
were sent to PSC Analytical Services, Inc, an Amencan Industrial Hygiene Association-
accredited laboratory in Reading, PA. One blank tube was also submitted. Analysis was
performed by means of a mercury vapor analyzer according to NIOSH Method 6009. A copy of
the analytical laboratory report is attached.
Jimmy Choy, Environmental Technician and Wagdi Abdelshahid, Industnal Hygienist from
ATC’s New York City office, conducted the sampling consistent with accepted industrial hygiene
practices The results represent the conditions on the day the samples were collected.
The sampling locations were 1®* floor Main Lobby, 2"'’ floor Hallway by Room 213 and 4“’ floor
hallway by Room 403.
Results
Mercury (Hg) was detected in these samples at levels that were indistinguishable from that
detected in the blank
The established regulatory value for mercury (O.lmg/m^) is intended for industnal workplace
exposures and is not generally applicable to office/school settings. There are no standards for
mercuiy in indoor air in non-industnal situations. The EPA has no standard or guidelme for
mercury vapor in ambient air.
CITy_21MC100_0 11095166
NYC-WTC_000310155
OCR can misread numbers and units. Confirm readings against the page image before using them.