NYC 9/11 Public Portal Document
Pace Analytical Services, Inc
1700 Elm Street-Suite 200
Minneapolis, MN 55414
?
^ace Analytical__________
Method Analysis Results 8290
Tel-612-607-1700
Fax 612-607-6444
Client - ATC ASSOCIATES
Client's Sample ID ATC-1114-89M-DX1
Lab Sample ID 104041546
Filename F21204B_08
Injected By MRO
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 11/14/2002
ICAL Date 11/25/2002 Received 11/15/2002
CCal Filename(s) F21204B_01 & F21204B_16 Extracted 11/25/2002
Method Blank ID BLANK-2453 Analyzed 12/05/2002 00:23
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2.3,7.8-TCDF ND 0.00200 2,3,7,8-TCDF-13C 2.00 86
Total TCDF ND 0.00200 2,3,7,8-TCDD-13C 2.00 86
1.2.3,7,8-PeCDF-13C 2.00 78
2.3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 74
Total TCDD 0.0043 0.00200 J 1,2,3,7,8-PeCDD-13C 2.00 77
1,2,3,4,7,8-HxCDF-13C 2.00 94
1,2,3.7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 95
2.3,4,7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 94
Total PeCDF ND 0.01000 1,2,3.7.8.9-HxCDF-13C 2.00 96
1,2,3.4,7,8-HxCDD-13C 2.00 96
1.2,3,7,8-PeCDD ND 0.01000 1.2,3,6,7,8-HXCDD-13C 2.00 97
Total PeCDD ND 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 87
1,2,3,4,7,8,9-HpCDF-13C 2.00 80
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 75
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 79
2,3,4,6,7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7.8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2.3,7,8-TCDD-37CI4 0.20 88
1,2,3,6,7,8-HxCDD ND 0.01000
1.2.3,7.8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.000072 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1,2,3,4.6.7,8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
OCDF ND 0.02000
OCDD 0.0720 0.02000 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis • = See Discussion
Report No.... 1065493
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003057974
NYC-WTC_000310043