Air sampling for silica, P.S. 234M, Mar 2002

Machine-extracted title · confidence 44%

ATC air monitoring report for silica-containing dust collected Feb 19, 2002 at the school.

NYC-WTC_000308967–000308968
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

r 104 East 25th Street

.TC ASSOCIATES INC. New York. New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306

March 8, 2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Re: Air Sampling for Silica P. S. 234M ATC Project No. 15-19125-0279

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of the results of air monitoring for silica-containing dust conducted on February 19, 2002, at the referenced school. The New York City Board of Education (BOE) requested this monitoring at the recommendation of Environ Corp., the consultant to the parents association.

SCOPE OF WORK

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists of ATC’s New York City office, collected the-samples.

ATC collected a total of seven (7) samples (and one blank) for respirable dust using pre-weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable) particles prior to deposition on the filters. All of the samples were collected indoors. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. Analysis for silica was performed by x-ray diffraction according to OSHA Method 142. A copy of the analytical report is attached.

Samples were obtained in the following locations: 1st floor Hallway, Cafeteria, Gymnasium, Auditorium, Room 211 South, Room 223 South, and Room 220 East.

The assessment was performed consistent with generally accepted industrial hygiene practices. As with all such assessments, there were inherent limitations created by constraints of time, operational and work practice variability, variations in air quality parameters and sampling and analytical accuracy.

The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presented in this report should be used by the Board of Education as a guide to assess the need for further improvements in current indoor air quality control activities.

CITY_21MC100_003057347

NYC-WTC_000308967

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000308967Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →