Air sampling for mercury, Stuyvesant HS, Feb 2002

Machine-extracted title · confidence 42%

Mercury vapor air sampling at Stuyvesant High School conducted February 20, 2002, per BOE request.

NYC-WTC_000308692–000308693
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St ▲ New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

February 27, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Mercury Vapor Stuyvesant High School ATC Project No. 15-19125-0246

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this report of air sampling for mercury vapor conducted on February 20, 2002, at the referenced school. The New York City Board of I Education (BOE) requested this sampling at the recommendation of H. A. Bader, a consultant to the parents association.

Scope of Work

ATC collected three (3) samples for mercury vapor using Carulite® (Hydrar) tubes connected to battery-powered sampling pumps calibrated to collect 0.2 liters of air per minute. Two samples were collected indoors and one was collected on the roof. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association-accredited laboratory in Reading, PA. One blank tube was also submitted. Analysis was performed by means of a mercury analyzer according to NIOSH Method 6009. A copy of the analytical report is attached.

Wagdi Abdelshahid and Tenzin Namgyal, Industrial Hygienists from ATC’s New York City office, collected the samples.

Results

Mercury (Hg) was detected in one sample (#Hg3, roof) at a level that was greater than the blank. When blank-corrected, the Hg concentration is reduced to 0.000052 mg/m^, which is less than 15% of the original concentration. Hg concentrations in the other three samples were aless than that found in the blank.

There are currently no federal ambient air standards for mercury. The Occupational Safety and Health Administration ’s (OSHA) Permissible Exposure Limit (PEL) for mercury is 0.1mg/m\ This is considerably above the levels that were detected or that would otherwise be expected in a school/office setting.

CITY_21MC100_003056496

NYC-WTC_000308692

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000308692Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000240507

Air sampling report for mercury vapor conducted on Feb 20, 2002 at Stuyvesant HS.

Similar indexed content

Compare copies and versions →