NYC-WTC_000429313
Scope of Work for 114 Liberty Street asbestos monitoring and sampling.
8 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗Staff qualifications for air and wipe sampling; technician certifications and experience.
NYC-WTC_000307894OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Air Sampling Technicians Air monitoring technicians must posses valid NYS Asbestos Project Sampling Technician (APST) certificates. Technicians must have performed air sampling for at least 6 months. At a minimum at least 5 Air Sampling Technicians must be assigned to this project. A single individual with Asbestos Project Monitor and Asbestos Project Sampling Teclmician certification shall not perform the functions of both Monitor and Technician during this project.
Wipe Sampling Technicians Wipe sampling technicians must have 1-year experience in wipe sampling for a variety of contaminants and have received state certified training in dust sampling. At a minimum at least 2 Wipe Sampling Technicians must be assigned to this project.
Equipment Sampling equipment must be in sufficient quantity to provide the amount and type of samples required for this project. At a minimiun the following equipment are required: air-sampling pumps with flow rate capacities of 2 to 10 liters per minute, tripods, rotometers, sample cassettes with mixed cellulose ester filters having pore size of 0.8|xm, micro vacuum, disposable porous cellulosic towellettes moistened with wetting agent and solvent-wetted sampling agent.
Analytical Laboratory The environmental laboratory must be certified by the New York State Department of Health. Certification for all the analytes specified herein must have been maintained for at least six (6) consecutive proficiency testing rounds. The laboratory must possess a gas chromatograph equipped with a capillary column and high-resolution mass spectrometer for analyzing dioxin and inductively coupled plasma for total metals. Cold V^r Method apparatus shall be used for mercury analysis.
Proof of qualifications must be presented to the NYCDEP prior to commencement of work. The NYCDEP reserves the right to disqualify any individual(s) fiom work on this project for non-compliance with these specifications or the requirements of applicable rules and regulations.
Specifications
It is anticipated that the work will be completed within three (3) weeks.
Sampling and Analytical Procedures for Lead, PAHs, Dioxin. Fibrous Glass, Silica, and Mercury
1. Sampling for lead, PAHs, dioxin, fibrous glass, crystalline silica and mercury shall be performed by the wipe sampling technician. A completed chain of custody must accompany all samples. A unique sample number shall be assigned to each sample. A complete written description and/or diagram shall clearly identify each sampling location.
2. Post cleaning air samples for fibrous glass and silica shall be collected concurrently with the asbestos clearance air sampling procedures specified herein. Five samples for fibrous glass and one sample for silica shall be collected in each apartment.
2 of 5
CITY_21MC100_000947615 NYC-WTC_000307894
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000429313
Scope of Work for 114 Liberty Street asbestos monitoring and sampling.
8 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362539
Scope of work for asbestos abatement monitoring and sampling at 114 Liberty Street, Manhattan.
9 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390014
Draft scope detailing asbestos abatement, cleaning, monitoring and clearance at 114 Liberty Street.
9 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000206792
Contract scope defining requirements for licensed abatement contractors to clean debris and monitor asbestos air sampling at 125 Cedar Street.
8 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000282459
Scope of work for 114 Liberty Street asbestos cleaning and monitoring; pre-abatement plan.
9 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000252321
Chain of custody/SC for 125 Cedar Street cleaning and asbestos monitoring scope.
9 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281926
Proposed on-site asbestos cleaning oversight and air monitoring requirements.
9 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362534
Draft DEP scope detailing on-site air monitoring and clearance sampling for asbestos abatement at 114 Liberty Street.
9 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390019
Draft scope detailing asbestos abatement, cleaning, monitoring and clearance at 114 Liberty Street.
9 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390024
Chain of custody document for asbestos-related sampling at 115 West Broadway project.
9 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140312
Requirements for technician certification and listing of analytical methods for asbestos, mercury, and other contaminants in air samples.
2 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140376
Initial draft outlining regulatory compliance, roles, and the scope of site inspections and cleaning activities for WTC impacted buildings.
2 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000455813
Scope of work for monitoring and cleanup of 125 Cedar Street interior; asbestos sampling included.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445849
New York DEP scope-of-work document for 125 Cedar Street remediation.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434571
Duplicate scope of work for interior cleaning and asbestos monitoring at 125 Cedar Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442641
Scope of work for asbestos surface monitoring and interior cleaning oversight at 125 Cedar Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441311
Scope of work for asbestos sampling and air monitoring at 125 Cedar Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435224
Scope for on-site asbestos air monitoring during interior cleaning at 125 Cedar Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Requirements for technician certification and listing of analytical methods for asbestos, mercury, and other contaminants in air samples.
Similar indexed content
NYC-WTC_000140376
Initial draft outlining regulatory compliance, roles, and the scope of site inspections and cleaning activities for WTC impacted buildings.
Similar indexed content
NYC-WTC_000429313
Scope of Work for 114 Liberty Street asbestos monitoring and sampling.
Similar indexed content
NYC-WTC_000362539
Scope of work for asbestos abatement monitoring and sampling at 114 Liberty Street, Manhattan.
Similar indexed content
NYC-WTC_000390014
Draft scope detailing asbestos abatement, cleaning, monitoring and clearance at 114 Liberty Street.
Similar indexed content