Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
z
■< z
■<
o o
co
§ NYC Emergency Response
Asbestos Air Sampling Results for Staten Island Landfill ■D
o c
o Sampling Date and Time: 10/18/01 0600 to 10/18/01 1900 CT
o
o o'
o ■D
cn PCM by NIOSH 7400 TEM (AHERA) O
o 3.
o Sampling Sampling Sample fZmm’ f/cc Structures on S/mm’ S~f/cc* 03
Date Sample No. Location Volume Matrix 0.5-5U O
o
o
10/18/01 03384 PLoc#1 720 Air <7.0 <0.004 2“ 2“ 35.56 0.0190 c
10/18/01 03385 PLoc#2 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 3
CD
10/18/01 033% PLoc#3 720 Air <7.0 <0.004 0 0 <8.89 <0.0048
10/18/01 03387 PLoc#4 720 Air <7.0 <0.004 0 0 <8.89 <0.0048
10/18/01 03388 PLoc#5 720 Air <7.0 <0.004 0 0 <8.89 <0.0048
10/18«)1 03389 Pl_oc#6 720 Air <7.0 <0.004 0 0 <8.89 <0.0048
10/18/01 03390 PLoc#7 720 Air <7.0 <0.004 0 0 <8.89 <0.0048
10/18/01 03391 PLoc#8 720 Air <7.0 <0.004 0 0 <8.89 <0.0048
10/18/01 03392 SLOC#9A 720 Air 7.64 0.004 1“ 1” 17.78 0.0095
10/18/01 03393 SLoc#9B 720 Air <7.0 <0.004 2“ 0 17.78 0.0095
10/18/01 03394 SLoc#10A 720 Air <7.0 <0.004 1“ 0 8.89 0.0048
10/18/01 03395 SLoc#10B 720 Air 7.64 0.004 1“ 1“ 17.78 0.0095
10/18/01 03396 WLoc#11 720 Air 11.48 0.008 1“ 0 8.89 0.0048
10/18/01 03397 WLoc#12A 2^ Air 16.56 0.009 4” 1“ 44.44 0.0238
10/18A)1 03398 WL0C#12B 7^ Air <7.0 <0.004 2" 1“ 26.67 0.0143
10/18/01 03399 B Loc #13 720 Air <7.0 <0.004 1“ 0 8.89 0.0048
10/18/01 03400 BLoc#14 720 Air <7.0 <0.004 1“ 0 8.89 0.0048
10/18/01 03401 T Loc #15 720 Air <7.0 <0.004 0 0 <8.89 <0.0048
10/18/01 03402 T Loc #16 504 Air <7.0 <0.005 3“ 0 26.67 0.0204
X)C# 04643 & 04644 ** Chrysotile; no other types of asbestos were detected.
NS: Not sampled
AF/ANF: Asbestos fibers/Non asbestos fibers
Sample volume is below recommended limit of the method:
‘Structure (S) roughly equivalent to fiber (f)
NA: not analyzed due to overloading of particulates
NC: Denotes not calculated due to no sample volume.
NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA)
o
Standard criteria; EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm’, volume 1200 L, for 25 mm filter (TEM)
H
K
I
to
ERT: 10/21/01 9:50 AM
o
o
o
I
o
o
co
o
co
co FK-10-18-01a
co
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000307530Source: NYC Law Department, mirrored locally