NYC-WTC_000287299
NYC sampling with date 01/13/2002; PCM by NIOSH 7400 and TEM AHERA analyses.
4 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC response asbestos air sampling results at specified sites, PCM/TEM.
NYC-WTC_000307202OCR status: ok · source: pdftotext
Z Z o NYC Response o Data Validation Date: 01/14/2002 co g Asbestos Air Sampling Results at Fixed Locations Sampling Date and Time: 01/12/02 0001 to 1200 O PCM by NIOSH 7400 TEM AHERA) I ■D o Sampling Sampling Sample Structures (#) c o CT o Date Sample No. Location Volume* Matrix f/mm^ f/cc 0.5m - 5m 5p S/mm^ S~f/cc** o o' o 01/12/02 RST-03130 L 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 ■D bJ 01/12/02 RST-03131 Ml 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 o o 01/12/02 RST-03132 N 44**.- Air <7.0 <0.061 0 0 <8.00 <0.0700 3. bJ QO 01/12/02 RST-03133 N-Duplicate 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 O 01/12/02 RST-03134 J 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 o 01/12/02 RST-03135 J-Duplicate 423 Air 7.64 0.007 0 0 <8.00 <0.0073 o c 01/12/02 RST-03136 Q 717 Air <7.0 <0.004 0 0 <8.89 <0.0048 3 CD 01/12/02 RST-03137 F 709 Air <7.0 <0.004 0 0 <8.00 <0.0043 01/12/02 RST-03138 A 645 Air 7.64 0.006 0 0 <8.00 <0.0048 01/12/02 RST-03139 C 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 01/12/02 RST-03140 B 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 01/12/02 RST-03141 H 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 01/12/02 RST-03142 I 666 Air <7.0 <0.004 0 0 <8.00 <0.0046 01/12/02 RST-03143 D 701 Air <7.0 <0.004 0 0 <8.89 <0.0049 01/12/02 RST-03144 K 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 01/12/02 T NS Air NS NS NS NS NS NS 01/12/02 RST-03145 U 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 01/12/02 RST-03146 V 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 01/12/02 RST-03147 s 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 01/12/02 RST-03148 p 720 Air <7.0 <0.004 0 0 <8.89 <0.0048 01/12/02 RST-03149 E 695 Air <7.0 <0.004 0 0 <8.00 <0.0044 01/12/02 RST-03150 w 720 Air 8.92 0.005 0 0 <8.00 <0.0043 01/12/02 FB011202 Field Blank 0 Air <7.0 n/a NA(=> NA<2> “na^ NA<^) 01/12/02 TB011202 Trip Blank 0 Air <7.0 n/a NA<^> na'^’ NA<^’ NA<^’
Sampling Locations: Key. A: NE corner of West Broadway & Barclay M: Western end of Harrison St. at West St. * Sample volume (liters) is below recommended B: SE corner of Church & Dey St. (on tree next to bulkhead) limit for the TEM method; volume is based on C: Trinity (a.k.a. Church) & Liberty Ml : West St. - 50 yards south of Harrison St. at bulkhead pump reading Cl: SW corner of Broadway & Liberty St, N: South side of Pier 25 (next to volleyball ct) ** Structure (S) is roughly equivalent to fiber (f) D: East end of Albany St. at Greenwich St. P: NE corner of South End Ave. & Albany *** Chrysotile E: Western end of Liberty St. at South End Ave Q: Barclay & West St. (center island) in *•** Extremely low sample volume collected F: Northern median strip of Vesey & West St proximity to USCG command post G: Church and Duane St. R: TAGA Bus Location NA*’’ - Not analyzed due to overloading of H: South side of Chase Manhattan Plaza at Pine St. S: Rector & South End particulates I: SE corner of Wall St. & Broadway T: Pier 6 Heliport NA*^’ - Not analyzed for TEM o J: NE corner of Warren & West St. U: Pier 6 Exit 2 n/a - Not applicable K: West St. & Albany in median strip V: Pier 6 Bus Sign NR - Not requested H K L; On walkway toward North Park rec area (north side W: Wash Tent Common Area NS - Sample not submitted due to no access I of Suyvesant High), access to TAGA bus area to station location bj
NIOSH 7400: Fiber Analysis of Air Samples via NIOSH 7400, Revision 3, Issue 2, 8/1S/94 o Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) o Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm^ volume 1200 L, for 25 mm filter (TEM) I o o co wo co cn FL-01-12-02-am cn co
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000287299
NYC sampling with date 01/13/2002; PCM by NIOSH 7400 and TEM AHERA analyses.
4 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307200
NYC response report for asbestos air sampling at multiple locations using PCM/ TEM.
4 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000288055
NYC response asbestos air sampling results at location, December 20, 2001.
4 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287296
NYC Response: asbestos air sampling results with time window and method.
4 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287522
NYC response asbestos air sampling at WTC, Nov 2001.
3 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287297
Asbestos air sampling at a NYC site; dates 01/07/02 and 01/11/02; analysis by PCM/NIOSH TEM AHERA.
4 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287523
NYC response asbestos air sampling at WTC, Nov 2001.
3 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000288064
NYC response asbestos air sampling results dated 12/20/01.
4 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287524
NYC response asbestos air sampling at WTC, Dec 2001.
4 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000331935
Asbestos air sampling results at WTC site with date and time window.
4 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287289
NYC Response: Asbestos air sampling results at [name] with time and method.
4 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000331918
NYC response: asbestos air sampling results at [name], TEM/NIOSH methods.
4 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000287299
NYC sampling with date 01/13/2002; PCM by NIOSH 7400 and TEM AHERA analyses.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307200
NYC response report for asbestos air sampling at multiple locations using PCM/ TEM.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287284
NYC Response: Asbestos air sampling results at [name], PCM and TEM AHERA methods.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000288055
NYC response asbestos air sampling results at location, December 20, 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287296
NYC Response: asbestos air sampling results with time window and method.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287522
NYC response asbestos air sampling at WTC, Nov 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000287299
NYC sampling with date 01/13/2002; PCM by NIOSH 7400 and TEM AHERA analyses.
Similar indexed content
NYC-WTC_000307200
NYC response report for asbestos air sampling at multiple locations using PCM/ TEM.
Similar indexed content
NYC-WTC_000288055
NYC response asbestos air sampling results at location, December 20, 2001.
Similar indexed content
NYC-WTC_000287296
NYC Response: asbestos air sampling results with time window and method.
Similar indexed content
NYC-WTC_000287522
NYC response asbestos air sampling at WTC, Nov 2001.
Similar indexed content