NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 6 pages

Proposed VOC air sampling plan, WTC, 10/23/01

Machine-extracted title · confidence 40%

Draft VOC plan to sample aldehydes, ketones, phenols, and particulates near WTC.

NYC-WTC_000306696–000306701
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 1. Overview of Sampling Plan *

Sample Location Method Sample Analyte Analysis Detection Limit Duration Collection street, roof, 1 ‘VOCs 2-4 hours TO-14 Summa canister GC/MS 2-4 mcg/m’ source street, roof, 2 Aldehydes 2-4 hours TO-11 DNPH cartridge HPLC 1-5 mcg/m3 source street,roof, 3.*Ketones 2-4 hours TO-14 Summa canister GC/MS 2-4 mcg/m3 source street,roof, 4. Phenolics 2-4 hours TO_14 Summa canister GC/MS 2-4 mcg/m3 source street,roof, 5.*Acrylates 2-4 hours source TO-14 Summa canister GC/MS 2-4 mcg/m3 lUII 6. Inorganic acids 8-16 hours roof, source EPA IP-9 Denuder/filter Chromatograp 1-2 mcg/m3

Adsorbent ton 7. Inorganic acids 2-4 hours N1OSH7903 Chromatograp 1 mg/m3 source Cartridge Adsorbent 8 Semi-volatiles 8-16 hours source only PUF GC/MS 1-2 mcg/m3 cartridge 9. TSP particulates 2-4 hours roof, source light scatter real-time DataRam ?

* All of the sampling will be done at all four community locations except for the acids (number 6); this sampling will only be done at three community sites (including at least one downwind location) due to equipment limitations. Immediately after sampling in the community, samples with this equipment will also be collected from the source;

* These chemicals were evaluated in the September 28, 2001 sampling.

Logistics:

Equipment and logistic limitations make it necessary for us to do the sampling over a two day period. Sampling is proposed for October 29 and October 30 or some other time later in the week.

Day 1 will include identification and preparation of the four community sampling locations, at least one of which will be downwind of the WTC. That evening sampling will be done for analytes 1 -5, 7 and 9 as listed in Table 1. The sampling for the analytes in items 6 and 8 of Table 1 will also be initiated and continued through the night into the next day until after the morning sampling event is completed. Additionally, because we only have three units to sample for the acids listed in item 6 analyte list number 6 (inorganic acid), we will collect samples at only one upwind location and at downwind locations. Similarly, we will only be able to do the same for the aldehyde sampling (analyte 2).

Day 2 will include the morning sampling at each location sampled the previous evening. Additionally, in the afternoon, sampling of the smoke from WTC disaster rubble as close to the rubble pile if not on it will be done for all of the analytes listed in Table 1. Where possible, these samples will be collected in duplicate.

CITY_DEP_WORBY_CANNATA_SUBP_000032640

NYC-WTC_000306697

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000306697Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →