Table 1. Overview of Sampling Plan *
Sample Location Method Sample Analyte Analysis Detection Limit Duration Collection street, roof, 1 ‘VOCs 2-4 hours TO-14 Summa canister GC/MS 2-4 mcg/m’ source street, roof, 2 Aldehydes 2-4 hours TO-11 DNPH cartridge HPLC 1-5 mcg/m3 source street,roof, 3.*Ketones 2-4 hours TO-14 Summa canister GC/MS 2-4 mcg/m3 source street,roof, 4. Phenolics 2-4 hours TO_14 Summa canister GC/MS 2-4 mcg/m3 source street,roof, 5.*Acrylates 2-4 hours source TO-14 Summa canister GC/MS 2-4 mcg/m3 lUII 6. Inorganic acids 8-16 hours roof, source EPA IP-9 Denuder/filter Chromatograp 1-2 mcg/m3
Adsorbent ton 7. Inorganic acids 2-4 hours N1OSH7903 Chromatograp 1 mg/m3 source Cartridge Adsorbent 8 Semi-volatiles 8-16 hours source only PUF GC/MS 1-2 mcg/m3 cartridge 9. TSP particulates 2-4 hours roof, source light scatter real-time DataRam ?
* All of the sampling will be done at all four community locations except for the acids (number 6); this sampling will only be done at three community sites (including at least one downwind location) due to equipment limitations. Immediately after sampling in the community, samples with this equipment will also be collected from the source;
* These chemicals were evaluated in the September 28, 2001 sampling.
Logistics:
Equipment and logistic limitations make it necessary for us to do the sampling over a two day period. Sampling is proposed for October 29 and October 30 or some other time later in the week.
Day 1 will include identification and preparation of the four community sampling locations, at least one of which will be downwind of the WTC. That evening sampling will be done for analytes 1 -5, 7 and 9 as listed in Table 1. The sampling for the analytes in items 6 and 8 of Table 1 will also be initiated and continued through the night into the next day until after the morning sampling event is completed. Additionally, because we only have three units to sample for the acids listed in item 6 analyte list number 6 (inorganic acid), we will collect samples at only one upwind location and at downwind locations. Similarly, we will only be able to do the same for the aldehyde sampling (analyte 2).
Day 2 will include the morning sampling at each location sampled the previous evening. Additionally, in the afternoon, sampling of the smoke from WTC disaster rubble as close to the rubble pile if not on it will be done for all of the analytes listed in Table 1. Where possible, these samples will be collected in duplicate.
CITY_DEP_WORBY_CANNATA_SUBP_000032640
NYC-WTC_000306697
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000362819
Preliminary VOC air sampling in three nearby locations to assess community exposure near WTC.
11 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000196071
Laboratory air monitoring report for 111-115 Broadway prepared by AKRF for Rosemnan & Colin LLP in February 2002.
12 shared non-person entities · 1 shared topics · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306310
AKRF air monitoring report for Rosenman & Colin LLP, Feb 21, 2002.
11 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153214
Draft plan outlining objectives to assess community exposure to VOCs and particulate matter near the WTC site.
18 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320530
Summary of VOC air samples taken around WTC site to assess exposure of nearby communities.
12 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317979
Summary of VOCs and aldehydes air samples near WTC debris pile and surrounding areas.
11 shared non-person entities · 1 shared topics · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337489
Air samples collected at three locations near the World Trade Center to screen for VOC exposure, Sep 2001.
12 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337695
Air samples at three locations near WTC measured VOCs for screening purposes, analyzed by GC-MS.
11 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337880
Air samples collected at three locations near the WTC to screen for volatile organic compounds.
11 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000204863
Summary report of volatile organic compound monitoring conducted by State and City Health Departments around the World Trade Center site on September 28, 2001.
12 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000150515
Report on volatile organic compound air samples collected by state and city health departments near the WTC site.
11 shared non-person entities · 1 shared topics · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199636
A report discussing volatile organic compound (VOC) levels found in the WTC debris plume versus residential areas to assess exposure risks.
12 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000153214
Draft plan outlining objectives to assess community exposure to VOCs and particulate matter near the WTC site.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153214
Draft plan outlining objectives to assess community exposure to VOCs and particulate matter near the WTC site.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447726
Chain-of-custody and project header for ambient air monitoring at 130 Liberty Street Deconstruction, May 2005.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000424950
Chain-of-custody for ambient air monitoring at 130 Liberty Street with LMDC/NYC agency info, May 2005.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349276
Table of contents for lab sections and data partitions.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162488
EPA memo to multi-agency distribution list regarding post-9/11 environmental response policy and coordination.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000153214
Draft plan outlining objectives to assess community exposure to VOCs and particulate matter near the WTC site.
Similar indexed content
NYC-WTC_000320530
Summary of VOC air samples taken around WTC site to assess exposure of nearby communities.
Similar indexed content
NYC-WTC_000317979
Summary of VOCs and aldehydes air samples near WTC debris pile and surrounding areas.
Similar indexed content
NYC-WTC_000337489
Air samples collected at three locations near the World Trade Center to screen for VOC exposure, Sep 2001.
Similar indexed content
NYC-WTC_000337695
Air samples at three locations near WTC measured VOCs for screening purposes, analyzed by GC-MS.
Similar indexed content