JN-(.7-2002 02:01- -ROM: TO:iei2S360041 P:6^14

KAM CONSULTANTS 35-40 36th Street Long Island City

J(arn NewYork, 11105 Tel:(m)729-W Fax: (718)729-1875

BULK SAMPLE ANALYSIS REPORT CLIENT: CPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768 BUILDING ADDRESS: 222 Broadway, Manhattan - 23rd,16th,I2th, 10th,3rd Floors PROJECT#’. Client Sample ID# 10-11 10-12 3-13 3-14 3-15 Lab Sample ID# 020516B-1567 020516B-1568 020516B-1569 020516B-1570 O2O516B-I571 Sample Location; Center on East Comer South West cst Side North West Set Back on Set Back Comer on Set Center on Set Center on Set Roof lOth Roof 10 th Back Roof Back Roof Back Roof Floor Floor 3rd Floor 3rd Floor 3rd Floor Homogeneit). Yes Yes Yes Yes Yes Sample Description. N/A N/A N/A N/A N/A

Coloi Gt Gt Gr Gr Or Texture. Mixed Mixed Mixed Mixed Mixed

Sample Treatment. None None None None None

Asbestos Present’ (Type & Percent) <1%CIIR <I%CHR ND <1%CHR ND Total Percent A-sbestos: <1% <1% 0% <1% 0%

Other Fibr Mat. (Type & Percent) 0% 0% 85%FBGL 0% 85%FBGL 2%CELL Non Fibr Mat. (Percent). >99% >99% 15% >99% 13% Date Received; 5/16/02 Dale of .Analysis; 5/16/02 Date of Report; 5/17/02

Analyst: Lab Manager: Roody Loi^ David Chen * Analysis of samples is performed by Polari^Light Microscopy (PLM) - Point Counting Method (EPA6OO/M4-82-020) / * AnalMical equipments. Slereobinocular microscope (MEIJI EMT-Serjal # 25930). Polarized Light Microscope (MEIJI ML-POL-Senal # 88034) * PLM IS not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-conlaining * Samples will be stored for ninety (90) days and then relumed to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory'. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government NYS-DO/f ELAP# 11273 WSr-NkTAP # 102047 AJHA#: 100269

Page 3 of 3

CITY_DEP_WORBY_CANNATA_SUBP_000007211

NYC-WTC_000306466

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000306466Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →