NYC 9/11 Public Portal Document
A. Scope of Work
NYCDEP Ambient Air Sampling
Name of School Location Type
1. High School for Economics & Finance Between 90 & 100 Trinity Place Ambient
2. IS 89 201 Warren Street__________ Aunbient
3. PS 234________________________ 292 Greenwich Street Ambient
4. Stuyvesant High School 345 Chambers Street Ambient
1. Continuous sampling for 8 hours at street level. The exact location will be identified by
the NYCDEP on the first day of sampling. Periodic examination of filters to ensure filter
does not become overloaded. (Flow rate at 2.5 liters/minute; Minimum sampling volume
1200 liters.)
2. Sample analysis utilizing PCM NIOSH 7400 method. Any levels found to be above 0.01
f/cc must be read utilizing AHERA method.
3. Sampling at the above locations to commence on October 15, 2001.
4. The PCM results shall be faxed to the NYC DEP (fax 718 595- 3744) by 9:00 a.m. the day
after sample collection. The TEM results shall be faxed to the NYCDEP within 12 hours
of the PCM results.
5. Sampling shall continue daily until notification by the NYC DEP to terminate sampling.
6. NYCDEP contact information as follows: R. Radhakrishnan (718) 595-3718
Penny Theodorellys (718) 595-3657