NYC 9/11 Public Portal Document OSHA WTC SAMPLING RESULTS SUMMARY AS OF 4/19/02 Page 1 of 3

U.S. Department of Latter j u Occupational Safety and Health Admtniatration K U' * OSHA SAMPLING RESULTS SUMMARY AS OF 4/19/( Asbestos

A total of 1316 samples (excluding bulk and blank samples) for asbestos have been taken. F 9/21, 177 samples were taken in the financial district. Since 9/21, sampling focused on the d< and those workers working in or immediately next to it. 151 of the samples analyzed exceeds limit via PCM analysis. However, upon further analysis using discriminating counting method; TEM analysis, the number of asbestos fibers found dropped dramatically to below detectable well below .1 f/cc.

Carbon Monoxide

A total of 129 personal samples of workers on the rubble pile showed results ranging from 1 ppm which are well below the OSHA permissible exposure limit of 50 PPM.

Noise

OSHA is monitoring the noise exposures of employees who perform (or work near) noisy ope such as jack hammering and drilling. To date the 159 samples collected indicate that employ exposures range from 73.7 dBA to 110.7 dBA. Twenty sample have exceeded the applicable permissible exposure limit of 90 dBA, mostly for concrete drilling, cutting, and jack-hammerin operations. Accordingly, OSHA continues to recommend the use of appropriate hearing prott noisy operations, and specifically, for concrete drilling, cutting, and jack-hammering operatior recommends dual hearing protection i.e. plugs and ear muff protection.

Total Dust (PNOR)

A total of 156 samples (excluding bulk and blank samples) for total dust in and around the de were taken. 5 samples were found to be in excess of the PEL for Total dust (ISmg/m^). The exposure was found on one operator who was exposed at approximately 4X PEL.

Respirable Silica

The overwhelming majority of 1080 silica samples (excluding bulk and blank samples) show i detectable levels of airborne silica. However, 72 exposures exceeded the PEL. The highest s result was approximately twenty-one times the OSHA limit (jack hammering concrete 16 feet grade). The other elevated exposures were approximately one to fourteen times the OSHA lii exposures occurred during: 1) pre-drilling /slurry wall 2) jack hammering, 3) rubble removal ai operations near the Winter Garden; 4) during the breaking up of concrete in the pit; 5) while < concrete slurry wall, 6) flagging operations in pit, and 7) while chipping concrete with power t< demolition activities at 7 WTC's parking garage. Most of the work areas where apparent over to silica occurred were in the rubble pile/pit; an area where OSHA continues to encourage th<

http;//www.osha.gov/nyc-disaster/summary.html 4/24/2002 CITY_21MC1OO_OO8123823

NYC-WTC_000304312

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000304312Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →