Summary: Particulate characterization in apartments, WTC

Machine-extracted title · confidence 29%

Summary report on particulate characterization in apartments after WTC destruction, prepared for multiple stakeholders.

NYC-WTC_000304209–000304258
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

11/19/01 MON 13:45 FAI 2123677356 us REP NADLER 121007

(HRGC/HRMS) in accordance with EPA SW-846 Method 8290. The samples for PCBs as Aroclors (PCB-I016, PCB-1221, PCB4232, PCB-1242, PCB-1248, PCB-1254, and PCB- 1260) were prepared and analyzed using gas chromatography with electron capture detection in accordance with EPA SW-846 Method 8082.

J. 2,2 Surface and Bulk Dust

The samples were prepared and analyzed to determine the presence of PCDDs, PCDFs, and PCBs as described in Section 3.2.1.

3.3 Results

3.3.1 Surface Wipe

Tabic 2 presents concentrations of PCDDs/PCDFs (expressed as 2,3,7,8- Tetrachlorobenzo-p-dioxin Equivalents') and PCBs, The concentrations of 2,3,7,8-TCDD Equivalents ranged from 0.0012 to 0.088 ng/nr. By comparison, the concentrations arc numerically lower than the background concentrations (0.05-0.29 ng/mY measured in commercial office buildings in the United States (Komtnsky and Kwoka, 1 ‘ ; ■ concentrations are also significantly less than the guideline (25 ug'ni 2,3, /,8- i CUD Equivalents) recommended by the National Academy of Sciences, Subcommittee on Dioxin (N AS 1988). All PCB concentrations were below the analytical limit of detection (<0.10 and are thus within comparative background levels (Kominsky et. al, 1989). The PCDDs and PCDFs were likely produced during the combustion of PCB-containing materials and chlorinated compounds such as PVC plastics. Historically, PCBs were used in dielectric fluids in electrical transformers and capacitors (e.g., fluorescent light ballasts and

1 The potential toxicity ofToixtunss of PCDDs and PCDFs in environmental samples is estimated by converting the respective concentrations of PCDDs and.PCDFs to 2,3,7,8-tettachlorodibenzo- p-dioxin (2,3,7,8-TCDD Equivalents) (EPA 1989). This mathematical conversion represents the estimated amount of 2,3,7,8-tetrachlorodibenzo-p-dioxin (i.e., the 2,3,7,8-TCDD isomer) that would have to be present to exhibit the same toxicity as the measured quantities of each of the various PCDDs and PCDFs that arc present in a sample.

8

CITY_21MC100_011115979

NYC-WTC_000304241

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000304241Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →