NYC 9/11 Public Portal Document
(HRGC/HRMS) in accordance with EPA SW-846 Method 8290. The samples for PCBs as
Aroclors (PCB-1016, PCB-1221, PCB-1232, PCB-1242, PCB-1248, PCB-1254, and PCB-
1260) were prepared and analyzed using gas chromatography with electron capture detection in
accordance with EPA SW-846 Method 8082,
3.2.2 Surface and Bulk Dust
The samples were prepared and analyzed to determine the presence of PCDDs, PCDFs,
and PCBs as described in Section 3.2.1.
3.3 Results
3.3.1 Surface Wipe
J
Table 2 presents concentrations of PCDDs/PCDFs (expressed as 2,3,7,8-
Tetrachlorobenzo-p-dioxin Equivalents') and PGBs. The concentrations of 2,3,7,8-TCDD
Equivalents ranged from 0.0012 to 0.088 ng/m\ By comparison, the concentrations are ’
numerically lower than the background concentrations (0.05-0.29 ng/m^) measured in
commercial office buildings in the United States (Kominsky and Kwoka, 1989). The
concentrations are also significantly less than the guideline (25 ng/m^ 2,3,7,8-TCDD
Equivalents) recommended by the National Academy of Sciences, Subcommittee on Dioxin.
(NAS 1988). All PCB concentrations were below the analytical limit of detection (<0.10
)Ug/m^) and are thus within comparative background levels (Kominsky et. al, 1989).
The PCDDs and PCDFs were likely produced during the combustion of PCB-containing
materials and chlorinated compounds such as PVC plastics. Historically, PCBs were used in
dielectric fluids in electrical transformers and capacitors (e.g., fluorescent light ballasts and
1
The potential toxicity of mixtures of PCDDs and PCDFs in environmental samples is estimated
by converting the respective concentrations of PCDDs and PCDFs to 2,3,7,8-tetrachlorodibenzo-
p-dioxin (2,3,7,8-TCDD Equivalents) (EPA 1989). This mathematical conversion represents the
estimated amount of 2,3,7,8-tetrachlorodibenzo-p-dioxin (i.e., the 2,3,7,8-TCDD isomer) that
would have to be present to exhibit the same toxicity as the measured quantities of each of the
various PCDDs and PCDFs that are present in a sample.
8
CONFIDENTIAL INSURANCE INFORMATION, CITY_2IMCI00_011803618
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000250946
OCR can misread numbers and units. Confirm readings against the page image before using them.