3.0 PCDDs, PCDFs, AND PCBs
3.1 Collection
3.1.1 Surface iVipe
Isopropanol-moistened 3-inch by 3-inch cotton gauze pads were used to collect surface
wipe samples from table tops and other furniture. The gauze pad was held with a gloved hand
(non-linear polyethylene-type glove). The surface was wiped using successive swaths first in
one direction, then in a second direction perpendicular to the first. Multiple gauze pads were
used as necessary depending on the surface dust loading. The gauze pad sample was then
placed in a clean glass sample container equipped with a Teflon-lined lid. The sample area was
measured and recorded.
3.1,2 Surface Dust
A new stiff bristle toothbrush was used to collect dust samples from furniture such as
i table tops and other furniture with a hard surface. The dust was swept into a pile and collected
using a scoop constructed of paper. The dust was then placed in a clean 50-ml polyethylene
I
centrifuge tube with a screw-cap lid. The sample area was measured and recorded.
3.1.3 Bulk Dust
Bulk dust samples were collected from exterior surfaces (including a window ledge and
a roof top) with heavy deposits of dust. The dust was placed in either a clean zip-lock plastic
bag or 50-inl plastic centrifuge tube.
3.2 Analysis
3.2.1 Surface IVipe
The samples were prepared and analyzed to determine the presence of tetra- through
octa-chlorinated dibenzo-p-dioxins and dibenzofurans and the respective 2,3,7,8-substituted
isomers using high-resolution gas chromatography/high-resolution mass spectroscopy
7
CONFIDENTIAL INSURANCE INFORMATION, CITY_2IMCl00_011803617
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000250945
OCR can misread numbers and units. Confirm readings against the page image before using them.