Biowatch system overview, 2003

Machine-extracted title · confidence 28%

Background on Biowatch air-sampling network and target organisms for NYC Fire Department briefing.

NYC-WTC_000303100–000303106
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Confidential Draft - For Internal Discussion Only K. Frucher 5/14/2003 - During the 1:00 call you will likely be told: o What type of agent it is; o How many sensors have picked up the agent (a more challenging scenario would involve a smaller number of sensors); o Positive sensor locations o The intensity of the reading o That the FD will need to be involved in helping to determining whether there has been a BT release capable of causing human illness and identifying the boundaries of the affected area by monitoring medical data and conducting environmental sampling o Other departments - e.g. Health and PD - will look for alternative explanations e.g. false positives in laboratory, information from intelligence sources in the meantime o You might also want ti discuss what information can be disseminated to the field (balancing need to not cause public panic) You will have until 2:30 to meet with internal FD staff and then will meet with Commissioners Kelly, Odermatt, Ward, Frieden, and Cardozo, as well as Mark Shaw and Peter Madonia at City Hall to discuss immediate steps. The last 15 minutes of the tabletop will be devoted to briefing the Mayor.

I. Scenario I: Multiple, Simultaneous (+) Samples found Several outdoor Biowatch units collect samples confirmed as positive at the Public Health Lab (PHL). These findings would suggest a significant outdoor release of a biological agent.

Command structure: According to DOHMH Protocol Version 1.8, DOHMH as incident commander, DOHMH EOC activated.

FDOC also activated

Threshold issues Specific to Department: 1. Ensure members participating in response have proper PPE (see attachment #2) - best if consistency Citywide (NIOSH/CDC) [likely Pl 00 masks for FFs; disposable goggles and laminated tyvek suits for EMS and CFR-d, tyvek suits, n-95 masks for patients, aerosol germicide cans to disinfect apparatus] (see attachment #3). 2. Consider giving responders prophylaxis if anthrax, plague, tularemia, brucellosis (identify allergies at annual medicals)

Depending on intensity of initial BT sample findings: 3. Consider not dispatching EMS or CFR-D units to possible infected zone without proper protective equipment. Note effect this may have on public awareness of issue. 4. Prepare to free up additional resources:

2

NYC-WTC_000303101

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000303101Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →