NYC-WTC_000248486
TEM asbestos identification and SAED/EDS, Stuyvesant HS, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗TEM analysis results for Stuyvesant High School floors 1-10, Oct 5, 2001.
NYC-WTC_000302855OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAF #10875 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identufication ty Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy lEDS) Method: ARERA Final Rule, ERA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample I dent: if i cat ion Analysis Parameters
Pro5 ect/SiC e: Stu^nzesant H.S., .34.5 Chambers St., NY, NY TEM Sample No.; 5609 6 0015 Floors 1-10 Date Received: 10/05/01 Grid Openings Analysed;__ 4
Project Semple No.: SHS-1>10-10/S-08 Average Grid Cpenine: 106.00 um
Air Volurae : 1872 liters Total Area Analyzed: 0.0450 mrn2
Filter Type: MCE 25 mm diam,, Pore Size: 0.45 um Analytical Sensitivity: 2 2.2 s/mm2 Effective Area: 38 5 mm2 0 . Q046 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total S i ng Ie Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct Struct Struct/mm2 Struct/cc nom/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 C . 0000 0
Ambiguous 0 0 0 0 0 0 0.0 C . 0000 0
Total asbestos (includes amoiguous structures) 0 0 0.0 0 . 0000 0 Non-AsbesCos 0 0 0 0 0 0 0.0 0 . 0000 N/A No Identification 0 0 0 0 0 0 0.0 0 . 0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty o: this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Rotran Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003112669
NYC-WTC_000302855
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000248486
TEM asbestos identification and SAED/EDS, Stuyvesant HS, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248465
TEM analysis data for Stuyvesant High School, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324287
TEM asbestos analysis with SAED/EDS for Economics & Finance site, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294146
TEM analysis report for Stuyvesant HS, including air volume and sample diameter.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205255
Laboratory analysis report for asbestos fibers in air samples collected at the High School for Economics and Finance.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330182
TEM asbestos analysis with SAED/EDS for HS site, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270586
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200240
Laboratory report documenting TEM analysis of air samples collected on October 4, 2001, using AHERA methods.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248492
TEM asbestos analysis for Stuyvesant High School; AHERA/ERA methods.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244642
TEM analysis of site samples with SAED/EDS identifications and volumes.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340268
Asbestos TEM analysis (SAED/EDS) for HS project site, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411482
TEM asbestos analysis for 328 W. 14th St. site, Sept 28, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000329958
Summary and conclusion of TEM results for Man Tech project.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248486
TEM asbestos identification and SAED/EDS, Stuyvesant HS, Oct 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248465
TEM analysis data for Stuyvesant High School, Oct 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324287
TEM asbestos analysis with SAED/EDS for Economics & Finance site, Oct 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294146
TEM analysis report for Stuyvesant HS, including air volume and sample diameter.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205255
Laboratory analysis report for asbestos fibers in air samples collected at the High School for Economics and Finance.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000248486
TEM asbestos identification and SAED/EDS, Stuyvesant HS, Oct 2001.
Similar indexed content
NYC-WTC_000248465
TEM analysis data for Stuyvesant High School, Oct 2001.
Similar indexed content
NYC-WTC_000324287
TEM asbestos analysis with SAED/EDS for Economics & Finance site, Oct 2001.
Similar indexed content
NYC-WTC_000294146
TEM analysis report for Stuyvesant HS, including air volume and sample diameter.
Similar indexed content
NYC-WTC_000205255
Laboratory analysis report for asbestos fibers in air samples collected at the High School for Economics and Finance.
Similar indexed content