NYC 9/11 Public Portal Document
Centers for Disease Control and Prevention
National Institute for Occupational Safety and Health
Interim Air Sampling Report
Monday, September 24, 2001
Investigators from the National Institute for Occupational Safety and Health (NIOSH) collected
bulk and air samples in areas immediately adjacent to the debris pile and on personnel actively
involved in rescue efforts on or in the vicinity of the debris pile to characterize potential
exposures. Below are the interim sampling results for Monday, September 24, 2001.
Bulk Samples
Metals
• 1 bulk sample of paint was collected from the steel superstructure of the WTC
o Calcium, chromium, iron, and zinc were found in concentrations greater than 10
mg/G
Air Samples
Carbon Monoxide
• 5 real-time personal breathing zone samples were collected for carbon monoxide
o Most 8-hour time-weighted average concentrations were below 25 ppm (a torch
cutter had an 8-hour time-weighted average concentration of 45 ppm)
o A single peak of 1170 ppm was observed on a steelworker on the debris pile
Metals
• 2 personal and 6 area air samples were collected for metals
o Nothing of concern was found regarding metal analysis
Respirable Dust
• 2 personal air samples were collected for respirable dust
o Personal sample 8-hour time-weighted average concentrations were below 0.09
mg/m^
K.M. Wallingford 10/4/01
CITY_21MC100_009028485
NYC-WTC_000302654
OCR can misread numbers and units. Confirm readings against the page image before using them.