Advisory on requirements for asbestos air sampling by DEP building owners/tenants.

NYC-WTC_000302628
Page image
Scanned page image, NYC-WTC_000302628
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Department of Air Sampling Advisory for Asbestos Environmental Protection 59-17 Junction Boulevard The following advisory was prepared to assist C ona. New York building owners/tenants with the performance ofair samplingfor asbestos nJ68-5107

Joel A. Miele Sr., P.E. Commissioner Persons who perform air sampling must possess valid New York State Asbestos Project Air Sampling Technician Certificates. Air sampling analysis must be Robert C. Avaltroni performed by a laboratory with ELAP accreditation. Deputy Commissioner Bureau of A minimum of five representative samples should be collected. In addition to these Environmental Compliance Tel (718)595-4418 5 samples, one representative area sample should be collected for every 5, 000 Fax (718) 595-4422 square feet above 25, 0000 square feet of floor space. The area must be dry before Scimpling.

The re-occupancy or clearance air monitoring is considered satisfactory when every PCM analysis sample is less than or equal to 0.01 fee or every TEM analysis sample is less than 7O.s/mm^.

PCM samples exceeding the 0.01 f/cc may be analyzed with TEM analysis to determine whether the measured fibers are asbestos fibers. Additional clean-up activities are necessary for re-occupancy if the levels are exceeded. .

For additional information regarding air sampling, please refer to the Asbestos Rules. A copy is posted on the Department’s web page.

If you have any questions, please call the Asbestos Control Program or contact the Department of Environmental Protection’s complaint center at (718) DEP-HELP (337-4357). Help Center operators will refer your call to Asbestos Control Program staff.

DSP

CITY_21MC100_010234795

NYC-WTC_000302628

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000302628Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000362359

Advisory: sampling requirements, ELAP accreditation, sample counts and re-occupancy criteria.

Similar indexed content

NYC-WTC_000307994

Advisory for building owners on asbestos air sampling and sampling frequency.

Similar indexed content

Asbestos air sampling advisory, NYC DEP

NYC-WTC_000203062

Department of Environmental Protection advisory providing guidelines for building owners and tenants regarding asbestos air sampling procedures.

Similar indexed content

Compare copies and versions →