NYC-WTC_000301914
TEM methodology section describing asbestos analysis procedures for school abatement air samples.
6 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗TEM methodology document for asbestos analysis described for air samples.
NYC-WTC_000301918–000301920OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
f
TRANSMISSION ELECTRON MtCRQSCOPY (TEMI METHODOLOGY
Transmission Electron Microscopy (TEM) is a technique, which focuses an electron beam onto a thin sample mounted in the microscope column (under a vacuum). As the beam transmits through the sample, an image resulting from varying density of the sample is projected onto a fluorescent screen. Air samples for TEM analysis can be collected on either mixed cellulose ester or polycarbonate filters and are prepared using direct transfer techniques (as per ERA regulations). Direct preparation allows for the transfer of a carbon- coated replica of the filter material (with embedded fibers and particulates, etc.) right on to a copper grid suitable for TEM analysis. Indirect transfer techniques require an intermediate step that may break-up fiber bundles, resulting in an increased fiber amount.
Several methods exist for the preparation and analysis of air samples by electron microscopy. Most signifi^cant are the mandatory and non-mandatory TEM methods set forth as appendices to 40 CFR 763, Subpart E ( AHERA Regulations). These methods are to be used for analysis of final clearance air samples on school abatement projects.
The analytical sensitivity is the airborne asbestos concentration represented by each fiber counted under the electron microscope. It is determined by the air volume collected and the proportion of the filter examined. This method requires that the analytical sensitivity be no greater than 0.005 structures/cc.
Sampling pumps must be calibrated and their flow indicators must register more than 1 but no more than 10 liters/min. Two (2) field blanks are to be taken by removing the cap for not more than 30 seconds. A sealed blank is to be carried with each sample set. Th+is representative cassette is not to be opened in the filed. These samples are submitted to the laboratory for quality control purposes. The sampling should be conducted for a period of time to conform at least a volume of 1200 liters of air. The samples are ’ater brought to a certified laboratory for the analysis.
CITY_21MC100_010315372
NYC-WTC_000301918
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000301914
TEM methodology section describing asbestos analysis procedures for school abatement air samples.
6 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108315
Transmission electron microscopy air monitoring report for asbestos analysis at townhouses, November 2001.
8 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000417088
Walk-through scheduling note for Independence Plaza contamination assessment.
8 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117493
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
4 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000231403
Document establishing the chain of custody for an asbestos assessment, bulk sampling, and air monitoring report at a building on Liberty Avenue.
5 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117668
Chain of custody documentation for bulk sampling and air monitoring at 385 South End Avenue Building 500.
4 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000097898
Environmental monitoring report prepared by ALC Environmental Inc. for the site at 71 Murray Street in October 2001.
4 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230980
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
4 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230955
Letter notifying the DEP of a change in property management for a building on Murray Street and providing updated contact information.
4 shared non-person entities · 1 shared topics · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117536
Chain of custody documentation for bulk sampling and air monitoring at 345 South End Avenue Building 100.
5 shared non-person entities · 1 shared topics · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342904
Environmental records showing sample custody and participants for site at 71 Murray Street.
4 shared non-person entities · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
4 shared non-person entities · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000365995
TEM methodology describing preparation and analysis for asbestos in air samples per AHERA/EPA guidelines.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301914
TEM methodology section describing asbestos analysis procedures for school abatement air samples.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342604
TEM methodology description for AHERA asbestos analysis.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363621
Detailed TEM prep and analysis methods per CFR AHERA guidelines.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108315
Transmission electron microscopy air monitoring report for asbestos analysis at townhouses, November 2001.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363619
TEM methodology overview for AHERA asbestos analysis in building samples.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000301914
TEM methodology section describing asbestos analysis procedures for school abatement air samples.
Similar indexed content
NYC-WTC_000108315
Transmission electron microscopy air monitoring report for asbestos analysis at townhouses, November 2001.
Similar indexed content
Walk-through scheduling note for Independence Plaza contamination assessment.
Similar indexed content
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
Similar indexed content
NYC-WTC_000231403
Document establishing the chain of custody for an asbestos assessment, bulk sampling, and air monitoring report at a building on Liberty Avenue.
Similar indexed content