z z ■<

-< o o co g o ■D I c o o INDOOR AIR QUALITY ANALYSIS CT o o' Ca3 o Project: Newmark & Co. Real Estate, Inc. CTSI Project #.-NY-442-01 Date: October 25, 2001 ■D o 00 3. 00 100 Gold Street 03 CD o o LOCATION TEMPERATURE RELATIVE CO2 (PPM) CO (PPM) TOTAL VOC'S TOTAL o c (’F) HUMIDITY PARTICULATE 3 CD (RH%) LEVELS X. Standard = Standard = Standard = Standard = Standard = Varies Standard= 68-74'1’ 30-50% 1 BBIB PPM 9.0 PPM per specific 0.015 mg/m^ parameter Outside 73.8 37.4 339 1.4 ND 0.400 ■ 6'*’ Fl. Section-A 75.5 43.7 602 1.3 ND 0.001 6“’Fl. Section-M 74.4 43.4 615 1.2 ND 0.001 6‘'’Fl.Section-Z 74.1 46.0 673 1.3 ND 0.02 6* Fl. Section-0 72.2 45.4 558 1.3 ND 0.001 8"^ Fl. Section-A 73.2 44.8 556 1.2 ND 0.002 S'^.Fl. SectiomM 73.5 44.5 676 1.2 ND 0.001 8"' Fl. Sectioi?^ 73.7 46.3 711 1.2 ND 0.001 8"’ Fl. Section^ 73.3 46.2 625 1.2 ND 0.001 7''* Fl. SectionT 74.8 41.5 580 1.2 ND 0.004 7'*' Fl. Section-'M 73.9 42.1 594 1.2 ND 0.005 7"’ Fl. Section^ 74.4 43.6 644 1.2 ND . 0.003 7‘'' Fl. Section-0 74.3 43.5 631 1.2 ND 0.003 5"^ Fl. Section-A 74.2 39.7 534 1.1 ND 0.004 5“* Fl. Section^ 74.2 38.9 539 1.1 ND 0.003 5^n. Section^ 72.8 43.3 587 1.2 ND 0.002

I o

K E 72.8 43.1 573 1.1 ND

"F = degrees Fahrenheit CO = Carbon monoxide CO2 = Carbon dioxide PPM = Parts Per Million 0.003

RH = Relative humidity ND = Non Detected I o' o 1 o o co co

CO STS I o

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000301889Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →