7 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301864
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000301864–000301865The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR status: ok · source: pdftotext
z o I s '2 o o INDOOR AIR QUALITY ANALYSIS ■D
o' Ca5 O 00 O> Project: Newmark Co. Real Estate, Inc. CTSI Project #: NY-442-01 Date: October 16, 2001 a cn O 100 Gold Street o o c
r LOCATION TEMPERATURE ("F) RELATIVE HUMIDITY CO2 (PPM) CO (PPM) TOTAL VOC'S TOTAL DUST LEVELS 3 1 o 12. (RH%) III Standard = Standard = Standard = Standard = Standard = Standard= 68-74“F 30-50% 1,000 PPM 9.0 PPM Varies per 15,000 ug/m’ specific parameter 9‘“ Fl. Section A 77.0 40.2 516 1.0 ND 77.1 9‘'‘ Fl. Section M 75.8 41.9 492 1.0 ND 79.2 9*'' Fl. Section Z 75.0 42.7 504 0.9 ND 62.5 9*F1. Section O 73.3 45.7 495 1.0 ND 63.9 Main Lobby________ 76.6 42.8 604 1.0 ND 73.8 Sidewalk 67.5 59.0 377 2.0 ND 142.3
“F = degrees Fahrenheit CO = Carbon monoxide CO2 = Carbon dioxide PPM = Parts Per Million RH = Relative humidity ND = Non Detected
o H K I
So I—i o o I o o co co KT II o
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
7 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301906
Indoor air quality analysis document with multiple measurements and locations.
7 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000302287
Indoor air quality data sheet for multiple sections of the building under NY-442-01.
7 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 100 Gold Street · 2 pages · confidence 0.85 · verify page 1
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Indoor air quality data sheet for multiple sections of the building under NY-442-01.
Similar indexed content
Similar indexed content
Similar indexed content
NYC-WTC_000301906
Indoor air quality analysis document with multiple measurements and locations.
Similar indexed content
Similar indexed content