Client-: Fine Organics Corporation Date: March 27,1992
Product: Envifcosolv 654 GR . SMI/REF: 9203028
Dilution: Neat & diluted 1:1 with ASTM D1193,Type IV, Page 3
SMI water
6. Cadmium Removal Test: The average weight loss of Cadmium from low-hydrogen
embrittlement cadmium plated steel specimens shall not exceed 10 milligrams
per coupon when tested in accordance with the applicable ASTM test method
or as follows:
(a) Each of three lx2x.040 inch 4130 steel panels, P/N 7452876-23
per Military Specification Mil-S-18729 shall be accurately
weighed and the weight recorded. Each of the weighed specimens .
shall be totally immersed in a minimum of 100 ml of the compound
for 24 hours. The concentration of the solution shall be that which
is recommended for use on the aircraft. The specimens shall then be
rinsed with distilled water, acetone and air dried. The specimens
shall be placed in an oven at 395°± 15°F'. (201.7 +8.3°C) for one (1)
hour and. allowed to cool to room; temperature. The specimens shall
be weighed and the average weight loss of the three specimens
recorded.
Neat 4.2 mg
1:1 2.6 mg Result Conform
7. Hydrogen Embrittlement: Hydrogen Embrittlement testing shall be in
accordance with ASTM F-519, Type Ic .
Result Conform Neat & diluted