EnviroSolv product test report, 1992

Machine-extracted title · confidence 32%

Laboratory product testing summary for EnviroSolv with dilution and method details.

NYC-WTC_000301857–000301859
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Client: Fine Organics Corporation Date; March 27,1992 Product: Envirosolv 654 CR SMI/REF: 9203028 Dilution; Neat & diluted 1:1 with ASTM D1193 Type IV Page 2 CSD #1 Reissued water SMI 1. Effect on Painted Surfaces Test: The material shall not. produce a decrease in paint film hardness greater than one pencil; that is the number of the next softer pencil, or any discoloration or stain­ ing when tested in accordance with ASTM F 502. At least 2 panels shall be used per test. Result Conform Neat & diluted 2. Residue Test: The material shall leave no residue or stain when tested in accordance with ASTM F-485. Result Conform Neat & diluted 3. Sandwich Corrosion Test: The compound shall not cause significant corrosion of aluminum alloy faying surfaces when tested in accordance with the applicable ASTM test method. Specimens after test, shall show a rating not worse than determined in accordance with ASTM.F- 1110-90 Standard Test Method Sandwich Corrosion Test.

1 ■2 3 4 2024-T3 Bane 2024-T3 7075-T6 Bare 7075-T6 anodized Alclad anodized alclad A. Diluted 1 1 1 1 B.Concentrate 1 1 1 1

C. Reagent Water 1 1 1 1

Result Conform Neat & diluted 4. Stress Crazing Test on Acrylic Plastics: The compound shall not cause crazing, cracking, or other attack on acrylic based plastics when tested in accordance with ASTM F-484, using Type C material at a stress level of 4500 psi. Result Conform Neat & diluted 5. Immersion Corrosion Test: The average weight loss of aluminum alloy specimens shall not exceed 10 milligrams perucoupon when-tested per ASTM F-483. The aluminum alloy 7075-T6 alclad coupons shall conform to Federal Specification QQ-A-250/13 Temp-T6, with corners and edges smoothed. Neat .6 mg 1:1 .9 mg Resul t Cnn-Form Npat Xi diluted

CITY_21MC100_0 04985066

NYC-WTC_000301858

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000301858Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000070845 · Box DEP Box 61

Chain of custody form for samples submitted to the Westchester County Department of Labs and Research in Valhalla, NY.

Similar indexed content

Compare copies and versions →