DCAS Bulk Sample Analysis, Health Dept. 125 [name]

Machine-extracted title · confidence 58%

Bulk sample analysis report for NYC-DCAS building at Health Department location.

NYC-WTC_000301827–000301829
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

DCAS Fax:212-663-8840 Oct 11 20C1 11:01 P.04 XAlKmJWS LangfiUndCii"/ HMYork.tnSS 1ri:(nD»'W Fa£i(71«)129-W

BULK SAMPLE ANALYSIS REPORT CLIENT; NYC-DCaS BUILDING ADDRESS; HEALTH DEPT. -125 Worth Street, Manhattan, NY' PROJECTS: Client Sample ID# : 1 2 J 4 3

Lab Sample ;D= ; 010917D-877 0109170-878 0109170-879 0109170-880 0109170-881

'Sample Loeaxion: lOih Floor lOrh Floor iOlh Floor 7ih Floor 7 th Floor Stair "A" West Stair "D" East Window Sil! Ncnh Stair "A" West Stair “D" East Elevator Lobby North

; HomogeneiT>': Yes Yes Yes Yes Yes

Sample Description: Floor Floor 5:1! Floor Floor Wipe wipe Wipe Wipe Wipe

Color: Blk Blk ■Blk Blk 31k

TexTure; Mixed Mixed Mixed Mixed Mixed

Sample Treatment; Nene None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat, (Type & Percent): 1OHSYNTH ,10%SYNTH SYoSYNTH 3%SYNTH 3%SYNTH 3%CELL 5%CELL 3%GELL 3%CELL Non Fibr. Mac. (Percent); 88% 85% 92% 89% 97% Date Received: 9/17/01 Date of Analysis 9/17/01 Dare of Report: 9/17/01

Analyst: Lab R.oodv Umns David Chen * Analysis of samples is oerformed b>f oiartzed Liabt Microscopy (PLM) - Point Countine Method (EPA 6a)/M4.S2-020) * Analycici! equipments: Stereobinocular microsccce (MEIJI EMT-Seriai * 25930"), Polarised Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistentlv reliable in detecting asbestos in floor coverinas and similar non-fnable organically bound materials Ouantitative transiaisiion electron microscopv is currenriy the only method that can be used to determine if this material can be considered or treated as non-asbestos-containina * Samples will be stored for ninety (90) davs and then returned co the client upon rsQuest * The results relate only (o the items calibrated or tested * The certiScate of report shall not be reproduced wt±out the written approvai of ths laboratory. * The report must not be used by the client to esaiai endorsement bv NVLAP or anv aaency of the US Oovenunent. NYS-DOH ELAP 11273 NEST-NyLAP^ I02C47 ALffA fr 10S269

1.

CITY_21MC100_011222436

NYC-WTC_000301827

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000301827Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000301830

Bulk sample analysis for DCAS project at 4M1 [name] building.

Similar indexed content

Compare copies and versions →