Table 9 Summary olF Airborne Fibers at Locations Where Asbestos Was Detected In Settled Surface Dust

Outdoor Areas in Lower Manhattan Building Area Asbestos in Dust SVF in Dust Aggressive Fibers in Air (PLMorTEM)’ (PLM)’’ Sampling^ (PCM/

1 Outdoor <1% 22% No 0.001 f/cc

2* Outdoor 1.3% 28% No 0.003 f/cc

5 Outdoor 3.4% 25% No 0.002 Pcc

7 Outtloor 1.7% 35% No <0.001 f/cc

15 Outdoor 1.9% 72% No <0.001 f/cc

27 Outdoor <1% 15% No <0.001 f/cc

Common Areas in Lower Manhattan Building Area Asbestos in Dust SVF in Dust Aggressive Fibers in Air (PLMorTEM)‘ (PLM)*’ Sampling' (PCM/

4 Conmon <1% 15% No 0.001 Pec 6 Common <1% 10% No <0.001 f/cc 10 Common 1.5% 20% No 0.002 f/cc

24 Common <1% 5% No 0.001 f/cc

27 Conmon <1% 10% No <0.001 f/cc

Residential Units in Lower Manhattan Building Area Asbestos in Dust SVF in Dust Aggressive Fibers in /Ur (PLMorTEM)" (PEM)” Sampling' (PCM/

4 Residence 1 <1% 2% Yes <0.001 f/cc 4 Residence 2 <1% 5% Yes 0.001 f/cc 5 Residence 1 <1% 10% Yes 0.002 f/cc 5 Residence 2 <1% 20% Yes <0.001 Vcc 9 Residence 1 <1% 2% Yes 0.001 Pcc

9 Residence 2 <1% 5% Yes 0.003 fZee 11 Residence 1 <1% ND Yes <0.001 t/cc 11 Resilience 2 1.5% ND Yes <0.001 ficc 15 Residence 1 <1% ND Yes <0.001 Pcc 27 Resilience 1 <1% 10% No <0.001 Pcc

a. Value shown is highest of die reported polarized light microscopy (PLM) and transmission electrnn microscopy (TEM) results for this area. b. SVF = swthetic vitreous fibers. Measured by PIM analysis. c. Aggressive sampling refers to a technique used in some residential units where the vacuum exfaauit (used for settled dust sample collection) was used to stir up the settled surface dust before the air sampling began. d. f/cc = the fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. e. Building 2 also had a co-located dust sample-, values represent the highest measured result.

61

CITY_21MC100_012183068

NYC-WTC_000301738

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000301738Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000276826

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

Similar indexed content

Compare copies and versions →