4.0 SAFETY AND HANDLING
Document Outline
EMERGENCY GUTDELINES
FIRE FIGHTING INFORMATION
HAZARDOUS REACTIONS
PREVENTIVE MEASURES
OTHER SAFETY AND HANDLING
EMERGENCY GUIDELINES A
DOT Emergency Guidelines:
1. Fire or explosion: Some may bum but none ignite readily. Some may polymerize (P)
explosively when heated or involved in a fire. Containers may explode when heated. Some may
be transported hot. /Asbestos; Asbestos, blue; Asbestos, brown; Asbestos, white/ ID
2. Health: Inhalation of material may be harmful. Contact may cause bums to skin and eyes.
Inhalation of asbestos dust may have a damaging effect on the lungs. Fire may produce
irritating, corrosive and/or toxic gases. Runoff from fire control may cause
pollution. /Asbestos; Asbestos, blue; Asbestos, brown; Asbestos, white/iSf 03
3. Public safety: CALL Emergency Response Telephone Number on Shipping Paper first. If
Shipping Paper not available or no answer, refer to appropriate telephone number listed on the
inside back cover. Isolate spill or leak area immediately for at least 10 to 25 meters (30 to 80
feet) in all directions. Keep unauthorized personnel away. Stay upwind. /Asbestos; Asbestos,
blue; Asbestos, brown; Asbestos, white/ Q3
4. Protective clothing: Wear positive pressure self-contained breathing apparatus (SCBA).
Structural firefighters' protective clothing will only provide limited protection. /Asbestos;
Asbestos, blue; Asbestos, brown; Asbestos, white/
5. Evacuation: Fire: If tank, rail car or tank tmck is involved in a fire, ISOLATE for 800 meters
(1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all
directions. /Asbestos; Asbestos, blue; Asbestos, brown; Asbestos, white/ CD
6. Fire: Small fires: Dry chemical, CO2, water spray or regular foam. Large fires: Water spray,
fog or regular foam. Move containers from fire area if you can do it without risk. Do not scatter
spilled material with high pressure water streams. Dike fire-control water for later disposal.
Fire involving tanks: Cool containers with flooding quantities of water until well after fire is