NYC 9/11 Public Portal Document
I Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
I we Analytical__________ Method 8290 Analysis Results
Tel; 612-607-1700
Fax- 612- 607-6444
I
T Client's Sample ID ATC-0214-89M-DX4
Client - ATC
Lab Sample ID 103331880
I Filename
Injected By
Total Amount Extracted
U20312A_14
CVS
1 m2 Matrix WIPE
% Moisture NA Dilution NA
I Dry Weight Extracted
ICAL Date
NA
03/12/2002
Collected
Received
02/14/2002
02/18/2002
CCal Fiiename(s) U20312A_06 & U20312A_21 Extracted 03/04/2002
Method Blank ID BLANK-1495 Analyzed 03/12/2002 20:57
I Native Cone EMPC
ng/m2
LRL
ng/m2
Internal
Standards
ng's
Added
Percent
Recovery
Isomers ng/m2
I 2,3,7.8-TCDF
Total TCDF
ND
0.0022
0.0023 A
0.0020 J
2,3,7,8-TCDF-13C
2,3,7,8-TCDD-13C
1.2.3,7.8-PeCDF-13C
2.00
2.00
2.00
70
67
67
2,3,7,8-TCDD ND 0.0040 A 2,3,4,7,8-PeCDF-13C 2.00 67
I Total TCDD
1,2,3.7,8-PeCDF
ND
ND
0.0020
0.0100
1,2,3,7,8-PeCDD-13C
1,2,3,4,7,8-HxCDF-13C
1,2,3,6,7,8-HxCDF-13C
2.00
2.00
2.00
71 *
89
69
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 74
I Total PeCDF
1,2,3,7.8-PeCDD
ND
ND
0.0100
0.0100
1,2,3,7,8,9-HxCDF-13C
1,2,3,4,7,8-HxCDD-13C
1.2,3,6,7,8-HxCDD-13C
2.00
2.00
2.00
77
103
69
Total PeCDD ND 0.0100 1.2,3,4,6,7,8-HpCDF-13C 2.00 83
I 1,2,3,4,7,8-HxCDF
1,2,3,6,7.8-HxCDF ND
0.013 0.0100 E
0.0100
1,2,3,4,7,8,9-HpCDF-13C
1,2,3,4,6,7,8-HpCDD-13C
OCDD-13C
2.00
2.00
4.00
83
95
75
2,3,4,6,7,8-HxCDF ND 0.0100
I 1,2,3,7,8,9-HxCDF
Total HxCDF
ND
0.0190
0.0100
0.0100 J
1,2,3,4-TCDD-13C
1,2,3,7,8,9-HxCDD-13C
2.00
2.00
NA
NA
1,2,3,4,7,8-HxCDD ND 0.0100 2.3,7,8-TCDD-37CI4 0.20 69
I 1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
Total HxCDD
ND
ND
0.0160
0.0100
0.0100
0.0100 J
I 1,2.3,4,6,7.8-HpCDF
1.2,3,4,7.8,9-HpCDF
Total HpCDF
0.0230
ND
0.0490
0.0100 J
0.0100
0.0100 J
Total 2,3,7.8-TCDD
Equivalence: 0.0025 ng/m2
(Using ITE Factors)
I 1,2,3,4,6,7,8-HpCDD
Total HpCDD
0.1000
0.1700
0.0100 B
0.0100
OCDF 0.0620 0.0200 J
I OCDD 1.2000 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration
I A = Detection Limit based on signal-to-noise measurement
J = Concentration detected is below the calibration range
E = PCDE Interference
S = Saturated signal
ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis ’ = See Discussion
Report No.... 02-1054211
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003096946
NYC-WTC_000300413
OCR can misread numbers and units. Confirm readings against the page image before using them.