NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
TM
we Analytical__________
Method Results 8290 Analysis
Tel: 612-607-1700
Fax’ 612- 607-6444
Client - ATC
Client's Sample ID ATC-0328-89M-DX2
Lab Sample ID 103435459
Filename U20425C_04
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/28/2002
ICAL Date 04/16/2002 Received 04/02/2002
CCal Filename(s) U20425C_01 & U20425C_16 Extracted 04/18/2002
Method Blank ID BLANK-1579 Analyzed 04/25/2002 20:33
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7.8-TCDF ND 0.0020 2,3,7,8-TCDF-13C 2.00 68
Total TCDF 0.011 0.0020 2,3,7,8-TCDD-13C 2.00 76
1,2,3,7,8-PeCDF-13C 2.00 80
2,3,7,8-TCDD ND 0.0020 2,3,4,7,8-PeCDF-13C 2.00 78
Total TCDD 0.035 0.0020 B 1,2,3,7,8-PeCDD-13C 2.00 88
1,2,3,4,7,8-HxCDF-13C 2.00 90
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 88
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 88
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 90
1,2,3,4,7,8-HxCDD-13C 2.00 97
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 84
Total PeCDD 0.045 0.0100 J 1,2,3,4,6,7,8-HpCDF-13C 2.00 94
1,2,3,4,7,8,9-HpCDF-13C 2.00 101
1,2,3,4.7,8-HxCDF ND 0.0100 1,2,3,4.6,7,8-HpCDD-13C 2.00 102
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 106
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 0.015 0.0100 J 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 85
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.120 0.0100
1,2,3,4,6,7,8-HpCDF 0.022 0.0100 J Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00063 ng/m2
Total HpCDF 0.022 0.0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.031 0.0100 J
Total HpCDD 0.067 0.0100
OCDF ND 0.0200
OCDD 0.100 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,S-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Mot Calculated
Nn = Value obtained from additional analysis • = See Discussion
Report No.... 02-1055820
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
.J without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003096914
NYC-WTC_000300391