Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
'ace Analytical__________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax' 612- 607-6444
Client - ATC
Client's Sample ID ATC-0321-89M-DX2
Lab Sample ID 103418851
I Filename F20417B_08
•J Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/21/2002
I CAL Date 04/12/2002 Received 03/26/2002
CCal Filename(s) F20417B_01 & F20417B_16 Extracted 04/12/2002
Method Blank ID BLANK-1566 Analyzed 04/18/2002 08:01
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.00200 2,3,7,8-TCDF-13C 2.00 90
Total TCDF ND 0.00200 2,3,7,8-TCDD-13C 2.00 89
1,2,3,7,8-PeCDF-13C 2.00 95
2,3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 90
Total TCDD 0.012 0.00200 1,2,3,7,8-PeCDD-13C 2.00 96
1,2,3,4,7,8-HxCDF-13C 2.00 120
1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 70
2,3,4,7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-l3C 2.00 101
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 97
1,2,3,4,7,8-HxCDD-13C 2.00 119
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 96
Total PeCDD ND 0.01 OOQ 1,2,3,4,6,7,8-HpCDF-13C 2.00 94
1,2,3,4,7,8,9-HpCDF-13C 2.00 88
J 1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 98
1,2,3,6,7,8-HxCDF ND 0.01000 - OCDD-13C 4.00 75
2,3,4,6,7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7.8-TCDD-37CI4 0.20 96
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1.2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.000088 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
OCDF ND 0.02000
OCDD 0.088 0.02000 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1055554
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003096905
NYC-WTC_000300386