NYC-WTC_000299241
TEM asbestos analysis results for exterior/interior areas, New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Asbestos TEM analysis data for exterior/interior of New Stuyvesant High School.
NYC-WTC_000300129–000300131OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Associates 104 East 25 Street, New York, NY 10010 Phone: (212) 353-8280 Fax; (212) 353-8306
Attn: Mr. Bernard Orlan Received: 5/4/02 6:30:00 PM N.Y.C. Board of Education ATCGroup#: 7634 28-11 Queens Plaza North Analysis Date: 5/4/02 Long Island City, NY 11101 Fax: (212) 475-4122 Phone: (212)477-8941 Project: New Stuyvesant H. S., 345 Chambers St., NY, NY Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Type(s) O.Sfi-S 5/t (S/cc) (S/mm^) (S/cc) Notes
I 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7634 -I
2 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7634 -2
3 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7634 -3
4 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7634 .4
5 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7634 -5
6 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7634 -6
7 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7634 -7
ROMAN PEYSAKHOV MICHAEL A. GORYCKl, Ph.D.
Analyzed by Approved by:
Disclaimer The laboratory is not responsible for data reported in structures/cc, which Is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data reported in structures/nnm'. This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples repotted above. Quality control data [Including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLMZTEM #101187-0, NY State ELAP #10879
Page I of 3
CITY_21MC100_003095995
NYC-WTC_000300129
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000299241
TEM asbestos analysis results for exterior/interior areas, New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380041
Asbestos TEM analysis results for New Stuyvesant H.S., Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299082
TEM analysis results for asbestos in air samples at the building.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300111
TEM asbestos analysis results for air samples at New Stuyvesant High School exterior/interior.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300177
TEM asbestos analysis results for exterior/interior areas under AHERA.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300298
TEM asbestos analysis report for exterior/interior of New Stuyvesant High School, May 23, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273506
TEM fiber analysis results for exterior/interior air at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300212
TEM analysis results for exterior/interior of building under AHERA.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298483
TEM asbestos analysis results for exterior/interior air samples.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273385
TEM asbestos analysis report for New Stuyvesant High School samples.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349388
TEM asbestos analysis results for New Stuyvesant High School samples.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191056
Comprehensive analytical report detailing transmission electron microscopy results for exterior and interior air samples from a New York City Board of Education high school.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000300111
TEM asbestos analysis results for air samples at New Stuyvesant High School exterior/interior.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299082
TEM analysis results for asbestos in air samples at the building.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299241
TEM asbestos analysis results for exterior/interior areas, New Stuyvesant High School.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349554
TEM asbestos analysis results; AHERA-compliant, New Stuyvesant HS, May 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298937
TEM asbestos analysis of exterior/interior building samples for New Stuyvesant High School, Feb 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000190835
Comprehensive laboratory report from ATC Associates detailing exterior and interior building fiber analysis performed for the NYC Board of Education on April 28, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis results for exterior/interior areas, New Stuyvesant High School.
Similar indexed content
Asbestos TEM analysis results for New Stuyvesant H.S., Feb 2002.
Similar indexed content
TEM analysis results for asbestos in air samples at the building.
Similar indexed content
TEM asbestos analysis results for air samples at New Stuyvesant High School exterior/interior.
Similar indexed content
TEM asbestos analysis results for exterior/interior areas under AHERA.
Similar indexed content