NYC-WTC_000299063
TEM asbestos analysis report for New Stuyvesant High School project, April 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Asbestos TEM fiber analysis report for New Stuyvesant High School, Apr 2002.
NYC-WTC_000299969–000299971OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Attn: Mr. Bernard Orlan Received: 4/13/02 4:45:00 PM N.Y.C. Board of Education ATC Group#: 7400 28-11 Queens Plaza North Analysis Date: 4/14/02 Long Island City, NY 11101 Fax: (212)475-4122 Phone: (212)477-8941
Project: New Stuyvesant H. S., 345 Chambers St., NY , NY Exterior and Interior of Building a
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Type(s) 0.5/i-S 5^ (S/cc) (S/mm^) (S/cc) Notes
17 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7400 -17
18 1928.00 0.0450 0 None Delected 0 0 0.0044 <22.24 < 0.0044 7400 -18
19 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 < 0.0045 7400 -19
20 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7400 -20
21 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7400 -21
MICHAEL A. GORYCKI, Ph.D. ROMAN PEYSAKHOV Anproved by:
Disclaimer The laboratory is not responsible for data reported in stnjctures/cc, which is dependent on volume collected by non-laboratory personnel. This m is only responsible for data reported in structures/mm’. This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879
Page 3 of 3
CITY_21MC100_003095391
NYC-WTC_000299971
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000299063
TEM asbestos analysis report for New Stuyvesant High School project, April 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000257208
AHERA asbestos TEM analysis results for exterior/interior of building at Stuyvesant HS.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299150
TEM asbestos analysis results for New Stuyvesant High School, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398491
TEM asbestos analysis data for exterior/interior areas at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300129
Asbestos TEM analysis data for exterior/interior of New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299168
TEM asbestos analysis results for New Stuyvesant High School, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298521
Chain of Custody for air monitoring data accompanying TEM analyses.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000190835
Comprehensive laboratory report from ATC Associates detailing exterior and interior building fiber analysis performed for the NYC Board of Education on April 28, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300111
TEM asbestos analysis results for air samples at New Stuyvesant High School exterior/interior.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300153
TEM asbestos analysis results for exterior and interior building areas under AHERA.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191016
Laboratory report from ATC Associates detailing transmission electron microscopy analysis of air samples for asbestos at a New York City Board of Education school.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191056
Comprehensive analytical report detailing transmission electron microscopy results for exterior and interior air samples from a New York City Board of Education high school.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000300153
TEM asbestos analysis results for exterior and interior building areas under AHERA.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299281
Chain-of-custody and TEM analysis summary for air samples from New Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298455
Analytical TEM asbestos results for exterior/interior building samples.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299990
TEM asbestos analysis report for exterior/interior of New Stuyvesant High School, Apr 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273520
TEM asbestos analysis results for exterior/interior air samples; includes AHERA methodology.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380916
TEM asbestos analysis per AHERA for Stuyvesant High School project documentation.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis report for New Stuyvesant High School project, April 2002.
Similar indexed content
AHERA asbestos TEM analysis results for exterior/interior of building at Stuyvesant HS.
Similar indexed content
TEM asbestos analysis results for New Stuyvesant High School, Apr 2002.
Similar indexed content
TEM asbestos analysis data for exterior/interior areas at New Stuyvesant High School.
Similar indexed content
Asbestos TEM analysis data for exterior/interior of New Stuyvesant High School.
Similar indexed content