Attn; Mr. Bernard Orlan Received: 6/26/02 9:00:00 PM N.Y.C. Board of Education ATC Group#: 8295 28-11 Queens Plaza North Analysis Date; 6/27/02 Long Island City, NY 11101 Fax; (212)475-4122 Phone: (212) 477-8941 Project: New Stuyvesant H. S., 345 Chambers St., NY , NY Exterior and Interior of Building and Roof

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Type(s} O.Sp-S 5p (S/cc) (S/mm^) (S/cc) Notes

17 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 8295 -17

18 1920.00 0.0450 0 None Detected 0 0 0.0045 < 22.24 <0.0045 8295 -18

19 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 8295 -19

20 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 8295 -20

21 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 8295 -21

ROMAN PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.

Analyzed by: improved by;

Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume id by non-laboratory personnel. This lab is only responsible for data reported in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request

Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879

Page 3 of 3

CITY_21MC100_003105997

NYC-WTC_000273522

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000273522Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000398491

TEM asbestos analysis data for exterior/interior areas at New Stuyvesant High School.

Similar indexed content

NYC-WTC_000380556

TEM asbestos analysis of air samples at New Stuyvesant High School, exterior/interior areas, Mar 2002.

Similar indexed content

NYC-WTC_000299990

TEM asbestos analysis report for exterior/interior of New Stuyvesant High School, Apr 2002.

Similar indexed content

NYC-WTC_000380886

TEM asbestos analysis results for New Stuyvesant High School, Mar 2002.

Similar indexed content

Compare copies and versions →