NYC-WTC_000297036
TEM asbestos in air samples from NYC Board of Education site; results documented and dated Mar 2002.
8 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
NYC-WTC_000299393OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet Client Name: NYC BOE Volume (liters): 1824 Lab Group #: 6779 Filter Type / Filter Area: MCE 3 85 Lab Sample #: 9 Grid Opening Bize: 0.01 !24 Client Sample #: F-9 Area Examined: 0 04496 nm- GRID BOX: .) Maenfficatk^ 20.000 GRID ID: Accelerating Voltage: 100 KeV # Grid Openings: 4 Analysis Date: 2/22/02
Analysis Performed By; ROMAN PEYSAKHOV
GO, i Structure Structure Type Length ID of Structure N or 0 EDS No ■=05p Amphibole! Nonasb (NonaJb F B C >=5li Chrys Ambig/ND \o Coord ) <5p Elements) ------------------------ OjLi i
EZ2H 7 P/ iV z
! Struct = >0.5p >5:1 Aspect Ratio Grid acceptance:
Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals laboratoiy identification criteria observed <10% particulate coverage >50% coverage ate least 20 unfolded or overlapped grid squares <5% F B C M v= EDS spectrum conforming to laboratory holes or opaque areas identification criteria observed Chrysotile AMPHIBOLES Amphibole F = Single Fiber Amosite B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos Tremolite M = Matrix Non-Ideniified Actinolite NSD = No Structures Detected
CITY_21MC100_0 03093500
NYC-WTC_000299393
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000297036
TEM asbestos in air samples from NYC Board of Education site; results documented and dated Mar 2002.
8 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000183009
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000214120
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000223039
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000296934
TEM asbestos analysis report for NYC BOE H.S.; includes lab data and results.
8 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299407
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297086
TEM asbestos in air samples for NYC BOE site; data and magnification details noted.
8 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297401
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000227296
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000223061
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000211990
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000215488
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000183009
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000214120
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000223039
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299407
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297401
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000227296
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000297036
TEM asbestos in air samples from NYC Board of Education site; results documented and dated Mar 2002.
Similar indexed content
NYC-WTC_000183009
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similar indexed content
NYC-WTC_000214120
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similar indexed content
NYC-WTC_000223039
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similar indexed content
NYC-WTC_000296934
TEM asbestos analysis report for NYC BOE H.S.; includes lab data and results.
Similar indexed content