NYC-WTC_000273440
TEM asbestos analysis report for air samples from New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Chain of Custody for air monitoring data with turnaround options.
NYC-WTC_000298597–000298599OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Associates 104 East 25 Street, New York, NY 10010 Phone; (212)353-8280 Fax:(212) 353-8306
Attn: Mr. Bernard Orlan Received: 5/28/02 7:30:00 PM N.Y.C. Board of Education ATC Group#: 7891 28-11 Queens Plaza North Analysis Date: 5/28/02 Long Island City, NY 11101 Fax: (212)475-4122 Phone: (212)477-8941
Project: New Stuyvesant H. S., 345 Chambers St., NY, NY Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Type(s) 6.S/1-5 5/t (S/cc) (S/mm^) (S/cc) Nctex
I . 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 789/ -/
2 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7891 -2
3 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7S9I -3
4 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 789/ -4
5 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 789/ -5
6- 1928.00 0.0450 0 None Detected 0 0 0.0044, <22.24 <0.0044 789/ -0
7 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 789/ -7
ROMAN PEYSA: MICHAEL A. GORYCKI, Ph.D.
Analyzed by: •proved by:
Disclaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data reported in structures/mm', This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality-control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited forNVLAP PLMZTEM #101187-0, NY State ELAP #10879
Page } of 3
CITY_21MC100_003090771
NYC-WTC_000298597
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000273440
TEM asbestos analysis report for air samples from New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273481
TEM asbestos analysis results for air samples collected at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300153
TEM asbestos analysis results for exterior and interior building areas under AHERA.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298483
TEM asbestos analysis results for exterior/interior air samples.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273506
TEM fiber analysis results for exterior/interior air at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191016
Laboratory report from ATC Associates detailing transmission electron microscopy analysis of air samples for asbestos at a New York City Board of Education school.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298368
Chain of custody form for air monitoring data associated with AHERA testing.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191415
ATC Associates report detailing exterior and interior asbestos fiber analysis by TEM microscopy for a New York City Board of Education high school project.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299990
TEM asbestos analysis report for exterior/interior of New Stuyvesant High School, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298504
Memo/letter transmitting TEM asbestos analysis results for New Stuyvesant H.S.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298688
TEM analysis results for exterior/interior air samples at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300045
TEM analysis of air samples at New Stuyvesant High School, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000298923
TEM asbestos analysis results for exterior/interior building samples.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298843
TEM asbestos analysis data for group 8179 at DOE site.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191801
Formal analytical report detailing transmission electron microscopy results for asbestos fiber analysis at a New York City Board of Education school.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298423
ATC TEM analysis results for asbestos at New Stuyvesant High School, exterior/interior areas.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000193840
Formal laboratory report detailing transmission electron microscopy results for asbestos clearance testing at a New York City Board of Education school.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299297
TEM/AHERA asbestos analysis data table with concentrations and notes.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis report for air samples from New Stuyvesant High School.
Similar indexed content
TEM asbestos analysis results for air samples collected at New Stuyvesant High School.
Similar indexed content
TEM asbestos analysis results for exterior and interior building areas under AHERA.
Similar indexed content
TEM asbestos analysis results for exterior/interior air samples.
Similar indexed content
TEM fiber analysis results for exterior/interior air at New Stuyvesant High School.
Similar indexed content