NYC-WTC_000300246
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Chain of custody form for air monitoring data accompanying TEM analyses.
NYC-WTC_000298382–000298384OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Associates 104 East 25 Street, New York, NY 10010 Phone: (212) 353-8280 Fax:(212) 353-8306
Attn: Mr. Bernard Orlan Received: 5/3/02 7:45:00 PM N.Y.C. Board of Education ATC Group#: 7621 28-11 Queens Plaza North Analysis Date: 5/4/02 Long Island City, NY 11101 Fax: (212) 475-4122 Phone: (212)477-8941 Project: New Stuyvesant H. S., 345 Chambers St,, NY , NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Type(s) O.Sfi-S 5p (S/cc) (S/mm^) (S/cc) Notes
1 1920,00 0,0450 0 None Detected 0 0 0,0045 <22.24 <0.0045 7621 -1
2 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7621 -2
3 1920.00 0.0450 0 None Detected 0 0 0.0045 <22,24 <0,0045 7621 ■'
4 1920.00 0.0450 0 None Detected 0 0 0,0045 <22,24 <0.0045 7621 -4
5 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7621 -5
6 . 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7621 -6
3 1928.00 0,0450 0 None Detected 0 ' 0 0.0044 < 22.24 <0.0044 7621 -7
MARKPEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: Approved by:
Oisdaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data repotted in stnrctuies/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLIWTEM #101187-0, NY State ELAP #10879
Page I of 3
CITY_21MC100_003090054
NYC-WTC_000298382
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000300246
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000184909
Formal laboratory report detailing TEM asbestos fiber analysis for a high school project dated June 18, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000193966
Formal laboratory report detailing transmission electron microscopy results for asbestos fiber analysis performed on air samples from a New York City Board of Education project.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299944
TEM asbestos analysis results for abatement sites, 04/10/02.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298624
Asbestos fiber TEM analysis report for New Stuyvesant High School, 2002 AHERA.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299981
Asbestos TEM fiber analysis report for New Stuyvesant High School, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299891
TEM asbestos analysis report for New Stuyvesant HS, exterior/interior areas, 04/02.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191254
Request form for TEM asbestos analysis at a high school submitted by ATC Associates on May 18, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300220
TEM asbestos analysis report for New Stuyvesant High School exterior/interior areas.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273394
Asbestos TEM analysis report for New Stuyvesant High School samples.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298751
TEM analysis results for air samples at New Stuyvesant High School, exterior/interior, received Jun 11, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298972
Asbestos TEM analysis results for New Stuyvesant High School, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000349565
TEM asbestos analysis results for exterior/interior of New Stuyvesant HS, May 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000179473
Laboratory data sheet from ATC Associates presenting transmission electron microscopy results for asbestos fiber analysis at a high school.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298617
Chain of Custody for air monitoring data with multiple turnaround times.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298751
TEM analysis results for air samples at New Stuyvesant High School, exterior/interior, received Jun 11, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299957
TEM asbestos fiber analysis results for exterior/interior of New Stuyvesant High School, Apr 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000193632
Analytical report from ATC Associates detailing transmission electron microscopy results for asbestos fibers in air samples from a New York City Board of Education high school on…
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
Similar indexed content
NYC-WTC_000184909
Formal laboratory report detailing TEM asbestos fiber analysis for a high school project dated June 18, 2002.
Similar indexed content
NYC-WTC_000193966
Formal laboratory report detailing transmission electron microscopy results for asbestos fiber analysis performed on air samples from a New York City Board of Education project.
Similar indexed content
TEM asbestos analysis results for abatement sites, 04/10/02.
Similar indexed content
Asbestos fiber TEM analysis report for New Stuyvesant High School, 2002 AHERA.
Similar indexed content