NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan February 13, 2002 Indoor Air Quality Assessment Page 4 H.S. for Leadership & Pub Service (M894) ATCProiectNo 15-19125-0290

TFOC Concentration

TVOCs were not detected anywhere inside the building (0 0 ppm) The outdoor TVOC concentration was also 0 0 ppm.

OBSERVATIONS

During this assessment, ATC noted the following’ • The interior of the building appeared clean and free of dust and debns; • The building was occupied at the time of the assessment, • No smoke odor was detected m the building;

FINDINGS

Based on the real-time measurements, the following findings are presented:

1. Concentrations of respirable particulates, CO and TVOCs, were within applicable standards and guidelines 1 2. Four (4) temperature measurements were below and one (1) temperature measurement was above the range of 68 to 75°F (at 50 percent relative humidity recommended by ASHRAE Standard 55-1992 dunng the heating season (wintertime conditions) 3. One hundred and thirty (130) of the relative humidity measurements were below the ASHRAE recommended range of 30 to 60 percent for occupant comfort The other four (4) measurements were within the recommended range. 4. Four (4) CO2 measurements were above the range recommended by ASHRAE 62-1999. All others were below the recommended maximum concentration.

It is our pleasure to provide these indoor air quality services to the New York City Board of Education If you have any questions about this report, please call (212) 353-8280, extension 261 or 212.

Sincerely, H TC ASSOCIA TES INC. Reviewed by.

Wiannis Efstathiou James R. Cohn, CEH, CSP Project Manager Regional Manager Industrial Hygiene Division

Attachment

NYC-WTC_000297725 CITY_21MC1OO_OO6797713

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000297725Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000297663

Indoor air quality measurements report dated Feb 5, 2002 for the referenced school.

Similar indexed content

NYC-WTC_000297790

ATC IAQ report for Feb 13, 2002 at the referenced school.

Similar indexed content

NYC-WTC_000297775

ATC IAQ report for Feb 26, 2002 at the referenced NYC school.

Similar indexed content

Compare copies and versions →