IAQ report, Feb 2002, High School for Leadership

Machine-extracted title · confidence 44%

Indoor air quality measurements report dated Feb 5, 2002 for the referenced school.

NYC-WTC_000297663–000297666
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr Bernard P Orlan February 6, 2002 Indoor Air Quality Assessment Page 2 H.S. for Leadership & Pub Service (MS94) ATCProiectNo 15-19125-0290

The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times The information presented in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities

EVALUATION CRITERIA

Currently, there are no regulatory standards for indoor air quality m non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 5S-1992), Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA),

Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times

TABLE 1 TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED

KaiHi l8&BaiW3iaa Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CO2) above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from (CO) USEPA NPAAQS) Respirable 65 micrograms per cubic meter USEPA NPAAQS Particulates (PM2.5) of air (pg/m^) 24-hour average Temperature Summer. 73-79°F at 50% RH ASHRAE 55 Winter. 68-75°F at 50% RH Relative Humidity 30-60% ASHRAE 55 Total Volatile Organic Compounds 1 ppm AIHA (TVOC) USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA = American Indrstnal Hygiene Association

CITY_21MC1OO_OO3O8795O

NYC-WTC_000297664

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000297664Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

IAQ report, Feb 12, 2002, ATC

NYC-WTC_000297722

Indoor air quality report for Feb 12, 2002 at the school, with monitoring details.

Similar indexed content

NYC-WTC_000297790

ATC IAQ report for Feb 13, 2002 at the referenced school.

Similar indexed content

NYC-WTC_000297826

ATC report of IAQ measurements collected Feb 15, 2002 at the referenced school.

Similar indexed content

Compare copies and versions →