PCB air sampling report, High School for Leadership, 2002

Machine-extracted title · confidence 42%

Lab report of PCB air samples collected December 30, 2001 at the BOE school.

NYC-WTC_000297565–000297566
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th Street New York, New York 10010 wwwatc-enviro com 212 353 8280 Fax 212 353 8306 ASSOCIATES INC.

January 9, 2002

Mr Bernard P Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Re: Air Samples for Polychlorinated Biphenyls High School for Leadership & Public Service (M894) 90 Trinity Place New York, NY 10006 ATC Project No. 15-19125-0290

Dear Mr Orlan

ATC Associates Inc. (ATC) is pleased to provide this report of the results of air samples for polychlorinated biphenyls (PCBs) collected on December 30, 2001, at the referenced location. The New York City Board of Education (BOE) requested these samples to evaluate possible contamination in the school building .

SCOPE OF WORK

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists of ATC’s New York City office, collected the samples

The PCB samples were collected using glass fiber filters and Florisil® tubes connected in series to battery-powered sampling pumps set at a flow rate of 0 2 liters per minute (1pm). Tlie sampling time was ten (10) hours The samples were analyzed by PSC Analytical Services, Inc (PSC), an American Industrial Hygiene Association-accredited laboratory in Reading, PA Analysis was performed according to NIOSH Method 5503 (gas chromatography/electron capture detector) A copy of the laboratory report is provided in tire Attachment

The sampling was performed consistent with generally accepted industrial hygiene practices There were inherent limitations created by constraints of time, operational and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy Tire results of the sampling represent conditions found on the dates the samples were collected

SAMPLING RESULTS

ATC submitted nine (9) samples for PCBs to PSC for analysis One blank was also submitted Each sample was analyzed for seven (7) PCBs with different chlorine content Samples were collected from (2) outdoor and seven (7) indoor locations.

CITY_21MC100_003087789

NYC-WTC_000297565

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000297565Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →