Letter: Air sampling for metals, HS for Leadership (M894)

Machine-extracted title · confidence 60%

ATC letter report detailing 2002 air sampling for metals at the High School for Leadership (M894).

NYC-WTC_000297525–000297526
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St New York, New York 10010 wwwatc-enviro com 212 353 8280 Fax 212 353 8306 ASSOCIATES INC

February 27, 2002

Mr Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Metals High School for Leadership & Public Service (M894) ATC Project No. 15-19125-0290

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for metals conducted on February 15, 2002, at the referenced school. The New York City Board of Education (BOE) requested these samples to determine if acceptable air quality is being maintained.

Scope of Work

ATC collected four (4) samples for metals m air. Samples were collected for ten (10) hours. Three (3) samples were collected inside the building and one (1) was collected outdoors. One blank filter was also submitted The samples were sent to PSC Analytical Services, Inc., an Amencan Industrial Hygiene Association-accredited laboratory m Readmg, PA Copies of the analytical reports are attached.

The samples were collected using 37 mm mixed cellulose ester filters connected to battery- powered sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and after each sampling period. Analysis was performed by NIOSH Methods 73OOM. Each sample was analyzed for a panel of eleven (11) metals. The metals were alummum (Al), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn), molybdenum (Mo), nickel (Ni) and zinc (Zn).

The locations of the samples were the Roof by air intake, 1“ floor Mam Lobby, 5“’ floor Hallway near the elevator and the 10* floor Hallway near the elevator.

The established regulatory values for metals are mtended for industrial workplace exposures and are not generally applicable to office/school settings. There are no standards for these materials in indoor air in non-industrial situations

Results

Chromium (Cr) was the only metal found above the limit of detection. It was also detected in the blank. Cr has typically been detected as a trace contammant of the filters. The CR concentrations in these samples are shown m the following table:

CITY_21MC100_003087744

NYC-WTC_000297525

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000297525Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000239977

Letter from ATC Associates reporting air sampling for metals conducted at the school in February 2002.

Similar indexed content

NYC-WTC_000239974

Letter from ATC Associates reporting air sampling for metals conducted at the school in February 2002.

Similar indexed content

Compare copies and versions →